Desa (V)T32N SERIES Continued, Manual Lighting Procedure, OPTIONAL Hand-Held, Remote Operation

Models: (V)T32N SERIES (V)T32P SERIES

1 40
Download 40 pages 37.59 Kb
Page 28
Image 28
Manual Lighting

OPERATIng fireplace

Continued

Manual Lighting

Procedure

1.Remove glass door (see Removing/Replacing Glass Door, page 24.)

2.Follow steps 1 through 7 under Lighting Instructions, page 27.

3.Depress gas control knob and light pilot with match.

4.Keep gas control knob pressed in for 30 seconds after lighting pilot. After 30 sec- onds, release gas control knob. Follow steps 9 through 12 under Lighting Instructions, page 27.

5.Replace glass door (see Removing/Replacing Glass Door, page 24).

OPTIONAL Hand-Held

IMPORTANT: Do not leave the selector switch in the REMOTE or ON position when the pilot is not lit. This will drain the battery.

On/Off Series

(Models HRC100 and HRC101)

Hold the control button on the hand-held remote until burner turns on. Hold the con- trol button again until burner turns off (see Figure 52).

To Lock press both buttons on hand-held remote control until light stops flashing. Hand- held remote control is now locked. If the fire is on it will be turned off automatically. In the locked state, the light will not light up when any button is pressed.

To Unlock press both buttons together on hand-held remote control until the light stops flashing. The hand-held remote is now unlocked.

REMOTE OPERATION

Note: All remote control accessories must be purchased separately (see Accessories, page 36). Follow instructions included with the remote control.

Indicator OPTIONAL Hand-HeldOn/Off Series Light

Control REMOTE OPERATION Button

NOTICE: You must light the pilot before using the hand-held re- mote control unit. See Lighting Instructions, page 27.

After lighting, let pilot flame burn for about one minute. Turn control knob to ON position. Adjust flame adjustment knob anywhere be- tween HI and LO. Slide the selector switch to the REMOTE position (see Figure 51). Note: The burner may light if hand-held remote was on when selector switch was last turned off. You can now turn the burner on and off with the hand-held remote control unit.

Figure 52 - On/Off Hand-Held Remote

Control Unit HRC100

Thermostat Series

(Model HRC200 and HRC201)

The hand-held remote can be operated using either the manual mode (MANU) or thermostatic mode (AUTO) (see Figure 53, page 30). To select Fahrenheit/Centigrade mode display, carefully press the ˚C/˚F mode button with the end of a paper clip or similar blunt object.

Manual Mode

1. Press the POWER and LOCK buttons together to turn on the hand-held remote

Blower Control Knob (Optional Accessory)

Variable Control Knob

control.

2. Press the MANU button to turn on the fireplace.

OFF

REMOTE

OFF

ON

ON

N

 

 

O

 

L

 

T

 

O

I

O

 

O

H

L

 

 

I

F

 

 

P F

 

 

 

 

 

3. Press the POWER and LOCK buttons together to turn off the fireplace.

Auto (Thermostatic) Mode

1. Press the POWER and LOCK buttons together to turn on the hand-held remote

Gas Control Knob in

Selector Switch in ON Position

Remote Position

Figure 51 - Setting the Selector Switch,

Gas Control Knob and Variable Contorl

Knob for Remote Operation

control.

2. Press AUTO button to select this mode.

3. Set the desired room temperature by press- ing the TEMP + or - buttons.

4. Press the POWER and LOCK buttons together to turn off the fireplace

28

www.desatech.com

111986-01D

Page 28
Image 28
Desa (V)T32N SERIES Continued, Manual Lighting Procedure, OPTIONAL Hand-Held, On/Off Series Models HRC100 and HRC101