Venting Installation

instructions

Continued

INSTALLATION PLANNING

There are two basic types of direct-vent in- stallation:

Horizontal Termination

Vertical Termination

Horizontal Termination Installation IMPORTANT: Horizontal square terminations require only inner portion of wall firestop. Hori- zontal installations using round termination require exterior portion of wall firestop available only in vent kit HTK (see Figure 14, page 11).

1. Set the fireplace in its desired location and deter-

mine the route your horizontal venting will take.

Do not secure the fireplace until all venting has

been installed. Some installations require sliding

the fireplace in and out of position to make final

venting connections. Figures 14 through 18 on

5.Carefully determine the location where the vent pipe assembly will penetrate the outside wall. The center of the hole should line up with the center-line of the horizontal vent pipe. Mark the wall for a 10" x 10" square hole. Cut and frame the square hole in the exterior wall where the vent will be terminated. If the wall being penetrated is constructed of noncom- bustible material, such as masonry block or concrete, a 7 3/4" hole with zero clearance is acceptable (see Figure 9).

Male

Slots

Female

Locking Lugs

Figure 8 - Vent Pipe Connections

pages 10 through 13 show different configura-

tions for venting with horizontal termination that

will help you decide which application best suits

your installation. Check to see if wall studs or

roof rafters are in the path of your desired vent-

ing route. If they are, you may want to adjust the

location of the fireplace.

2. Direct vent pipe sections and components are

Vent Opening

Combustible Wall

10"

10"

10" Inside Framing

designed with special twist-lock connections.

(Framing

Twist-Lock Procedure: The female ends of the

Vent Opening

Detail)

pipes have locking lugs (indentations). These

lugs will slide straight into matching slots on

the male ends of adjacent pipes. Push pipe sec-

tions together and twist one section clockwise

approximately one-quarter turn until the sections

are fully locked (see Figure 8). Note: Horizontal

runs of vent must be supported every three feet.

Use wall straps for this purpose.

3. Use a 45° elbow to connect venting system

to fireplace flue collar. The elbow is designed

to be twist-locked onto the flue collar as

described in step 2. IMPORTANT: Do not

attempt to alter the configuration of the elbow

by cutting, twisting, bending, etc.

4. Assemble the desired combination of pipe and

elbows to the fireplace flue collar. If there are

long portions of venting run, pre-assembled

pipe sections may be installed as subassem-

blies for convenience.

Noncombustible Wall

7 3/4"

Center of

Hole

Figure 9 - Vent Opening Requirements

111986-01Dwww.desatech.com

Page 9
Image 9
Desa (V)T32P SERIES, (V)T32N SERIES installation manual Installation Planning

(V)T32N SERIES, (V)T32P SERIES specifications

Desa (V)T32P and (V)T32N Series are cutting-edge technological offerings from Desa, known for their precision and reliability in high-performance applications. These series are designed to meet the evolving needs of engineers and manufacturers in various sectors, including automotive, aerospace, and industrial automation. Both series boast an impressive array of features that enhance functionality, efficiency, and safety.

One of the main features of the (V)T32P Series is its advanced processing capabilities. These models come equipped with powerful processors that enable rapid data handling and processing. This makes them ideal for applications that require real-time monitoring and control. Additionally, the series supports a wide range of input and output options, allowing seamless integration into diverse systems.

The (V)T32N Series, on the other hand, focuses on connectivity and data communication. These models incorporate state-of-the-art networking technologies, including Ethernet, Wi-Fi, and various industrial communication protocols. This enables easy integration into existing networks, promoting collaborative environments where information can be shared quickly and securely. The series also features enhanced security protocols to safeguard sensitive data against cyber threats.

Both series are built with durability in mind. They utilize robust materials and advanced manufacturing techniques to withstand harsh operating conditions, reducing downtime and maintenance costs. Additionally, the devices in these series have been designed to be energy-efficient, adhering to industry standards and providing cost savings over time.

Another significant characteristic of both the (V)T32P and (V)T32N Series is their user-friendly interfaces. With intuitive controls and clear display options, users can easily navigate through settings and configurations, ensuring quick adaptation and efficient operation. This ease of use is further complemented by comprehensive documentation and support resources provided by Desa, ensuring that users can maximize the capabilities of their systems.

In summary, the Desa (V)T32P and (V)T32N Series represent a leap forward in technology for professionals seeking reliable, efficient, and user-friendly solutions. Their powerful processing capabilities, advanced connectivity options, durability, and ease of use make them ideal choices for a variety of applications, ensuring that users are well-equipped to tackle the challenges of modern engineering and manufacturing.