Desa (V)T32P SERIES CAUTION: Do not vacuum if pieces are hot, Continued, pilot and burners, logs

Models: (V)T32N SERIES (V)T32P SERIES

1 40
Download 40 pages 37.59 Kb
Page 31
Image 31
 CAUTION: Do not vacuum if pieces are hot.

Cleaning and

Maintenance

Continued

pilot and burners WARNING: Only parts sup- pliedbythemanufacturershould be used when replacing broken or damaged glass door panel (see Replacement Parts, page 36). This glass door panel is a complete unit. No substitute materials may be used.

logs CAUTION: Wear gloves and safety glasses while handling or removingbrokenglass.Donotre- moveifglassishot.Keepchildren and pets away from glass.

If glass has been broken, carefully remove glass door (see Removing/Replacing Glass Door, page 24). Vacuum all glass pieces with a shop vac.

venting system CAUTION: Do not vacuum if pieces are hot.

Use only the tempered glass door replacement intended for this fireplace (see Replacement Parts, page 36, for detail on ordering). No substitutions may be made. See Removing/Replacing Glass Door, page 24, for instructions for replacing glass door.

Manual background WARNING: Do not operate fireplace with the glass door removed, cracked, or broken.

pilot and burners

Remove ember material before cleaning burners and replace when cleaning is complete.

Burner and controls should be cleaned with compressed air to remove dust, dirt, or lint.

Use a vacuum cleaner or small, soft bristled brush to remove excess dust, dirt, or lint.

logs

If you remove logs for cleaning, refer to Install- ing Logs, Lava Rock, and Glowing Embers, page 25, to properly replace logs.

Use a vacuum cleaner to remove any carbon buildup on logs.

Replace log(s) if broken. See Replacement Parts on page 36.

Replace ember material periodically as needed. See Replacement Parts on page 36.

venting system

Conduct annual inspection of the venting system following these guidelines:

1.Check areas of venting system that are ex- posed to the weather for corrosion (rust spots or streaks and, in extreme cases, holes). Have these items replaced immediately by a quali- fied service person.

2.Remove the vent cap and shine a flashlight into the vent. Remove any foreign material.

3.Check for evidence of excessive condensation. Continuous condensation can cause corrosion of caps, pipes, and fittings and can be caused by having excessive lateral runs, too many elbows, or exterior portions of the system being exposed to cold weather.

4.Inspect joints to verify that no pipe section or fitting has been disturbed and loosened. Check mechanical supports such as wall straps for rigidity.

111986-01D

www.desatech.com

31

Page 31
Image 31