Desa S26PTA Installation, Continued, Installing Blower Control Housing, Routing Power Cord

Models: S26PTA S26NTA

1 28
Download 28 pages 30.26 Kb
Page 13
Image 13
Figure 17 - Installing Blower Control

Installation

Continued

12.Using the four screws previously removed, mount blower assembly to stove by reat- taching blower brackets to rear panel (see Figure 16). Tighten screws securely.

13.Install plastic control knob onto output shaft of speed control housing (see Figure 17). Place speed control housing just inside control com- partment door in front of stove (see Figure 17).

14.Using two screws provided in blower kit, mount blower speed control housing to mount- ing tab in left side of lower control compart- ment (see Figure 18).

15.Check to make sure that the power cord is completely clear of blower wheel and there are no foreign objects in blower wheel.

16.Carefully replace stove top panel. Align holes and replace six screws removed in step 1, page 12.

17.Peel off the backing paper and stick the sup- plied wiring diagram decal on the stove floor as shown in Figure 18.

18.Plug power cord into a convenient 3-prong grounded wall receptacle near the stove.

Figure 18 - Routing Power CordWARNING:ElectricalGround- ing Instructions: This appliance is equipped with a three-prong (grounding) plug for your protec- tion against shock hazard and should be plugged directly into aproperlygroundedthree-prong receptacle.

Blower

Blower Bracket

Firebox

Top

Figure 16 - Removing Blower Brackets from Stove and Attaching to Blower

19.Using speed control knob, turn blower on and check for operation.

20.All remaining parts from blower kit may be discarded.

Manual backgroundManual background Blower Speed

Control Housing

Figure 17 - Installing Blower Control

Housing

Power

SpeedManual backgroundManual background Cord

Control

Housing

Control Manual backgroundManual backgroundManual background

Knob

Manual background WARNING: Never attempt to service heater while it is plugged in, operating or hot. Burns and electrical shock could result. Only a qualified service person should service or repair heater.

If any of the original wire as supplied with the appliance must be replaced, it must be replaced with 105°C wire or it’s equivalent.

Manual background WARNING: Label all wires prior to disconnec- tion when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

120 Vac.

 

 

Variable

 

 

 

 

 

60 Hz. .

 

Fan Switch

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

78 Amps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Off

On

 

 

 

 

 

110/115

 

Black

Black

 

Blower

 

 

V.A.C.

Black

 

 

 

 

Black

Motor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Green

 

 

 

 

 

 

 

 

 

 

 

 

 

White

 

 

 

 

White

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DESA Heating Products, Bowling Green, KY

Wiring Diagram Decal

Figure 18 - Routing Power Cord

110361-01G

www.desatech.com

13

Page 13
Image 13
Desa S26PTA, S26NTA installation manual Installation, Continued, Installing Blower Control Housing, Routing Power Cord