AIR FOR COMBUSTION

AND VENTILATION

Continued

Unusually tight construction is defined as construction where:

a.walls and ceilings exposed to the out- side atmosphere have a continuous water vapor retarder with a rating of one perm (6 x 10-11kg per pa-sec-m2) or less with openings gasketed or sealed and

b.weather stripping has been added on openable windows and doors and

c.caulking or sealants are applied to areas such as joints around window and door frames, between sole plates and floors, between wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical and gas lines and at other openings.

If your home meets all of these three cri- teria, you must provide additional fresh air. See Ventilation Air From Outdoors, page 7.

If your home does not meet all of the three criteria above, proceed to Determining Fresh-Air Flow For Fireplace Location.

Confined and Unconfined Space

The National Fuel Gas Code, ANSI Z223.1/NFPA 54 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed*, through openings not furnished with doors, are considered a part of the unconfined space.

*Adjoining rooms are communicating only if there are doorless passageways or ventilation grills between them.

DETERMINING FRESH-AIR FLOW FOR heater LOCATION

Determining if You Have a Confined or

Unconfined Space

Use this work sheet to determine if you have a confined or unconfined space.

Space: Includes the room in which you will install heater plus any adjoining rooms with doorless pas- sageways or ventilation grills between the rooms.

1.Determine the volume of the space (length x width x height).

Length x Width x Height =__________cu. ft. (volume of space)

Example: Space size 20 ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) = 2560 cu. ft. (volume of space)

If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space.

2.Multiply the space volume by 20 to determine the maximum Btu/Hr the space can support.

___________ (volume of space) x 20 = (Maxi- mum Btu/Hr the space can support)

Example: 2560 cu. ft. (volume of space) x 20 = 51,200 (maximum Btu/Hr the space can support)

3.Add the Btu/Hr of all fuel burning appliances in the space.

Vent-free fireplace

____________ Btu/Hr

Gas water heater*

____________ Btu/Hr

Gas furnace

____________ Btu/Hr

Vented gas heater

____________ Btu/Hr

Gas fireplace logs

____________ Btu/Hr

Other gas appliances*

+__________ Btu/Hr

Total

=__________ Btu/Hr

*Do not include direct-vent gas appliances. Di- rect-vent draws combustion air from the outdoors and vents to the outdoors.

Example:

 

30,000

 

Gas water heater

_

Btu/Hr

Vent-free fireplace +

26,000

Btu/Hr

Total

=

56,000

Btu/Hr

4.Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.

__________Btu/Hr (maximum the space can support)

__________Btu/Hr (actual amount of Btu/Hr used) Example: 51,200 Btu/Hr (maximum the space

can support)

56,000 Btu/Hr (actual amount of Btu/Hr used)

The space in the above example is a confined space because the actual Btu/Hr used is more than the maxi- mum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows:

A.Rework worksheet, adding the space of an adjoin- ing room. If the extra space provides an unconfined space, remove door to adjoining room or add ventilation grills between rooms. See Ventilation Air From Inside Building, page 7.

B.Vent room directly to the outdoors. See Ventila- tion Air From Outdoors, page 7.

C.Install a lower Btu/Hr heater, if lower Btu/Hr size makes room unconfined.

www.desatech.com110361-01G

Page 6
Image 6
Desa S26NTA AIR for Combustion Ventilation, Determining FRESH-AIR Flow for heater Location, Confined and Unconfined Space

S26PTA, S26NTA specifications

Desa S26PTA and S26NTA represent the forefront of agricultural technology, offering robust solutions tailored for modern farming needs. These innovative systems cater specifically to agricultural producers looking to enhance efficiency, streamline operations, and improve yields.

One of the main features of Desa S26PTA is its advanced precision agriculture capabilities. Equipped with state-of-the-art GPS technology, it enables farmers to accurately map their fields, monitor crop health, and apply inputs like fertilizers and pesticides with pinpoint accuracy. This not only conserves resources but also minimizes environmental impact, leading to more sustainable farming practices. Additionally, the S26PTA offers real-time data analytics that helps farmers make informed decisions based on current field conditions.

On the other hand, the S26NTA focuses on nutrient management, delivering a comprehensive solution for soil health. Its integrated sensor technology allows for continuous monitoring of soil conditions, assessing moisture levels, pH, and nutrient content. Farmers can access this data through a user-friendly interface, empowering them to optimize their soil management strategies. By fostering healthier soils, the S26NTA contributes to stronger crop development and increased productivity.

Both the S26PTA and S26NTA leverage Internet of Things (IoT) technologies, connecting various sensors and agricultural equipment. This technological integration provides a holistic view of farming operations, ensuring that farmers can monitor and control their systems remotely. The ability to receive alerts and notifications regarding equipment performance or potential issues is invaluable for proactive management.

Moreover, these systems are designed to be user-friendly, with intuitive interfaces that cater to farmers of all tech-savvy levels. Training and support are also integral parts of the package, ensuring that users can maximize the potential of these advanced technologies.

In conclusion, Desa S26PTA and S26NTA exemplify the evolution of agriculture through technology. Their focus on precision farming, nutrient management, and IoT integration offers powerful tools that enhance productivity and sustainability. As the agricultural sector continues to embrace digital transformation, solutions like these will play a crucial role in shaping the future of farming. Farmers adopting these technologies can look forward to optimized operations, improved crop yields, and a positive environmental impact.