CHECK GAS TYPE

Installation

Continued

CLEARANCES TO COMBUSTIBLES WARNING: Never install the heater

in a bedroom or bathroom

in a recreational vehicle

where curtains, furniture, clothing or other flammable objects are less than 42" from the front, top or sides of the heater

in high traffic areas

in windy or drafty areas

Minimum Wall and Ceiling ClearancesCAUTION:Thisheatercreates warmaircurrents.Thesecurrents move heat to wall surfaces next to heater. Installing heater next to vinyl or cloth wall coverings or operatingheaterwhereimpurities (such as, but not limited to, to- bacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist, may discolor walls or cause odors.

Important: Vent-free heaters add moisture to the air. Although this is beneficial, installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Combustion and Ventilation, page 5.

CHECK GAS TYPE

Use correct gas type (natural or propane/LP). If your gas supply is not correct, do not install heater. Call dealer where you bought heater for proper type heater.

Figure 4 - Minimum Clearance to Walls WARNING: This appliance is equipped for natural or pro- pane/LP gas. Field conversion is not permitted.

CLEARANCES TO COMBUSTIBLES

Manual background WARNING: Maintain the minimum clearances. If you can, provide greater clearances from floor, ceiling and adjoining side and back walls.

Carefully follow the instructions below. This stove is a freestanding unit designed to set directly on the floor. Important: You must maintain minimum wall and ceiling clearances during installation. The minimum clearances are shown in Figure 4. Measure from outermost point of stove top.

Minimum Wall and Ceiling Clearances

(see Figure 4)

A. Clearances from outermost point of stove top to any combustible side wall should not be less than 12".

B. Clearances from outermost point of stove top to any combustible back wall should not be less than 6" (Includes corner installations).

C. Clearances from the stove top to the ceiling should not be less than 48".

Ceiling

Front View

48"

Minimum

Side Wall

12"

 

 

 

12"

Side Wall

 

Minimum

 

 

 

 

 

Minimum

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Back Wall

 

 

6 "

 

 

Minimum

 

12 "

12 "

 

Minimum

Minimum

 

Side

Side

 

Wall

Wall

Corner

 

Wall

 

 

6 "

 

Top View

Minimu

 

 

 

 

Front of

 

 

Stove Unit

Wall

6 "

 

 

Minimum

 

 

 

Ceiling

 

 

48"

 

 

Minimum

 

 

Back Wall

 

 

6"

 

 

Minimum

Side View

Floor

Figure 4 - Minimum Clearance to Walls

and Ceiling

www.desatech.com110361-01G

Page 8
Image 8
Desa S26NTA Installation, Continued, Check Gas Type, Clearances To Combustibles, Minimum Clearance to Walls and Ceiling