Troubleshooting
Continued
WARNING: If you smell gas
•Shut off gas supply.
•Do not try to light any appliance.
•Do not touch any electrical switch; do not use any phone in your building.
•Immediately call your gas supplier from a neighbor’s phone. Fol- low the gas supplier’s instructions.
•If you cannot reach your gas supplier, call the fire department.
IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time.
OBSERVED PROBLEM | POSSIBLE CAUSE | REMEDY | ||||
|
|
|
|
|
|
|
Heater produces unwanted | 1. | Heater burning vapors from | 1. | Open window and ventilate | ||
odors |
| paint, hair spray, glues, clean- |
| room. Stop using odor caus- | ||
|
|
| ers, chemicals, new carpet, |
| ing products while heater is | |
|
|
| etc. (See IMPORTANT state- |
| running | |
|
| 2. | ment above) | 2. | Refill supply tank (propane/LP | |
|
| Low fuel supply (propane/LP | ||||
|
| 3. | only) | 3. | only) | |
|
| Gas leak. See Warning | Locate and correct all leaks | |||
|
|
| statement above |
| (see Checking Gas Connec- | |
|
|
|
|
| tions, page 10) | |
|
|
|
|
|
|
|
Heater shuts off in use (ODS | 1. | Not enough fresh air is avail- | 1. | Open window and/or door for | ||
operates) | 2. | able | 2. | ventilation | ||
|
| Low line pressure | Contact local propane/LP gas | |||
|
| 3. | ODS/pilot is partially | 3. | company | |
|
| Clean ODS/pilot (see Cleaning | ||||
|
|
| clogged |
| and Maintenance, page 16) | |
|
|
|
|
|
|
|
Gas odor even when control | 1. | Gas leak. See Warning | 1. | Locate and correct all leaks | ||
knob is in OFF position | 2. | statement above |
| (see Checking Gas Connec- | ||
|
| Control valve defective | 2. | tions, page 10) | ||
|
|
|
| Replace control valve | ||
|
|
|
|
|
| |
Gas odor during combustion | 1. | Foreign matter between con- | 1. | Take apart gas tubing and | ||
|
| 2. | trol valve and burner | 2. | remove foreign matter | |
|
| Gas leak. See Warning | Locate and correct all leaks | |||
|
|
| statement above |
| (see Checking Gas Connec- | |
|
|
|
|
| tions, page 10) | |
|
|
|
|
|
|
|
Burnerflameisexcessivelylarge | 1. | Excessive line or manifold | 1. | Check manifold pressure and | ||
and is very near or touches the | 2. | pressure | 2. | correct as needed | ||
top of firebox | Dirty primary air holes | Clean burner air holes (see | ||||
|
|
|
|
| Cleaning and Maintenance, | |
|
|
|
|
| page 16). |
www.desatech.com | 21 |