Desa SBVBN(C) Connecting Stove/Burner System To Gas Supply, Checking Gas Connections, Continued

Models: SBVBP(C) SBVBN(C)

1 36
Download 36 pages 34.13 Kb
Page 14
Image 14
CONNECTING STOVE/BURNER SYSTEM TO GAS SUPPLY

14

CAST IRON STOVE AND B-VENT BURNER SYSTEM INSTALLATION

Installing Gas Piping to Stove Location (Cont.)

Connecting Stove/Burner System to Gas Supply

Checking Gas Connections

CAST IRON STOVE AND B-VENT BURNER SYSTEM INSTALLATION

Continued

We recommend that you install a sediment trap/drip leg in supply line as shown in Figure 29, page 13. Locate sediment trap/drip leg where it is within reach for cleaning. Install in piping system between fuel supply and burner system. Locate sediment trap/drip leg where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into burner system gas controls. If sediment trap/drip leg is not installed or is installed wrong, burner system may not run properly.

CONNECTING STOVE/BURNER SYSTEM TO GAS SUPPLY

Installation Items Needed

5/16" hex socket wrench or nut-driver

sealant (resistant to propane/LP gas, not provided)

1.Open lower door panel.

2.Route flexible gas line (provided by installer) from equipment shutoff valve to burner system (see Figure 30). Route flexible gas supply line and attach to valve.

3.Check all gas connections for leaks. See Checking Gas Connections, column 2.

To Flare Fitting on

Control Valve

Equipment

Shutoff Valve

Flexible Gas Line from

To Gas Supply

Equipment Shutoff Valve

Provided by Installer

(Natural)

 

To External Regulator

 

(Propane/LP)

Figure 30 - Flexible Gas Line

 

CHECKING GAS CONNECTIONS

CHECKING GAS CONNECTIONS WARNING: Test all gas piping and connections, internal and external to unit, for leaks after installing or servicing. Correct all leaks at once.

Manual background WARNING: Never use an open flame to check for a leak. Apply noncorrosive leak test solution to all gas joints. Bubbles forming show a leak. Correct all leaks at once.

Pressure Testing Gas Supply Piping System

Test Pressures In Excess Of 1/2 PSIG (3.5 kPa)

1.Disconnect appliance with its appliance main gas valve (control valve) and equipment shutoff valve from gas supply piping systems. Pressures in excess of 1/2 psig (3.5 kPa) will damage burner system gas regulator.

2.Cap off open end of gas pipe where equipment shutoff valve was connected.

3.Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas burner system or opening main gas valve located on or near gas meter for natural gas burner system, or using compressed air.

4.Check all joints of gas supply piping system. Apply noncorro- sive leak test solution to all gas joints. Bubbles forming show a leak. Correct all leaks at once.

5.Reconnect burner system and equipment shutoff valve to gas supply. Check reconnected fittings for leaks.

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)

1.Close equipment shutoff valve (see Figure 31).

2.Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas burner system or opening main gas valve located on or near gas meter for natural gas burner system, or using compressed air.

3.Check all joints from propane/LP supply tank or gas meter to equip- ment shutoff valve (see Figure 32 for propane/LP or Figure 33 for natural, page 15). Apply noncorrosive leak test solution to all gas joints. Bubbles forming show a leak. Correct all leaks at once.

Open

Equipment

Shutoff Valve

Closed

Figure 31 - Equipment Shutoff Valve

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundForManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background.Manual backgroundManual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual background

106828-01C

Page 14
Image 14
Desa SBVBN(C), SBVBP(C) Connecting Stove/Burner System To Gas Supply, Checking Gas Connections, Continued, For..com