Safety Information

Continued

18.Do not attempt to light one burner off of the other. Use one match per burner.

19.Do not overlap or point burners at each other.

20.Do not raise burner heads and cover air inlet holes in mixing tube with burner head bracket.

21.Wing nuts and burner heads become very hot during operation. Do not attempt to adjust burner position while heater is operating. Allow 15 minutes to cool.

22.For use with 20 lb. propane cylinders only.

23.Due to the high surface and exhaust temperatures, adults and children must observe clearances to avoid burns or clothing ignition.

24.Do not move, handle or service while hot or burning. Do not attach or remove a hot or operating heater from the propane/LP tank. Severe burns may result.

25.Before each use, check heater for leaks. Never use an open flame to check for leaks. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks.

26.Keep all connections and fittings clean. Make sure propane/LP tank valve is clean. Check "O" ring on heater inlet fuel valve connector for damage before each use. Replace if worn or damaged.

27.The LP gas cylinder must be constructed and marked in accordance with the speci- fications for the LP gas cylinders of the US Department of Transportation (DOT) or Transport Canada.

28.Use only in accordance with local codes or, in the absence of local codes, with the

CAN1- B149 Installation Code.

29.Storage of heater is permissible only if the cylinder is disconnected and removed from heater.

30.Always remove heater from propane tank after each use. Always store propane tank outdoors in a well ventilated space out of the reach of children. Never store propane tank in a building, garage, or any other enclosed area. Never store propane tank near high heat, open flame, or where temperatures exceed 100° F (38° C).

Assembly Instructions

2 Burner Models ONLY

1.Inspect the heater components for pos- sible shipping damage. If any is found, im- mediately notify the dealer. Check to make sure that all components are included with your heater (see pages 8 and 9).

2.Insert the piezo ignitor into the bracket on the burner support bracket as shown in Figure 1. Tighten the piezo mounting nut. Do not over tighten the nut.

3.Connect the burner hoses together as shown in Figure 2. Wrench tighten to insure leak tight connection.

4.Mount the burner assembly onto the sup- port arm using the burner head mounting brackets and brass screws as shown in Figure 3. Place side of bracket into the slot on support arm. Secure with screw. Make certain that the air holes on the sides of the burner tube are not blocked. Securely tighten the burners into place.

Piezo Ignitor

Piezo

Mounting

Nut

Burner

Support

Bracket

Figure 1 - Installing Piezo Ignitor

Figure 2 - Attaching Burner Hoses to

Regulator

Burner Head

Assembly

Slot Support

Arm

 

Air Hole

Brass Screw

Burner Head

Mounting Bracket

 

Figure 3 - Attaching Burner Head

Assembly to Support Arm

www.desatech.com118127-01B

Page 4
Image 4
Desa 000-24, TC111 8, TC110 8 Assembly Instructions, Burner Models only, Piezo Ignitor Mounting Nut Burner Support Bracket

000-24, 050 BTU, 000-12, TC110 8, TC111 8 specifications

Desa 050 BTU, TC111 8,000-12, and TC110 8,000-24 are innovative heating solutions designed to meet the diverse needs of modern consumers. These models combine advanced technology with user-friendly features, making them ideal choices for both residential and commercial applications.

One of the standout characteristics of the Desa 050 BTU is its energy efficiency. This model is engineered to provide optimal heating while minimizing energy consumption. Users can benefit from lower utility bills and a reduced carbon footprint. The unit’s heat output capacity ranges from 8,000 to 12,000 BTUs, making it versatile enough for different room sizes and configurations.

The TC111 8,000-12 model also emphasizes energy efficiency, designed with cutting-edge technology to ensure effective heat distribution. The unit operates quietly, ensuring a comfortable environment without disruptive noise. The heater’s adjustable thermostat allows users to set their preferred temperature, contributing to personalized comfort and convenience.

In contrast, the TC110 8,000-24 offers a higher heat output, making it suitable for larger spaces or environments that require consistent heating. This model features a robust build designed to withstand frequent use, ensuring reliability and longevity. It also comes equipped with a user-friendly control panel, simplifying the operation process for any user.

Both the TC111 and TC110 models incorporate advanced safety features, including automatic shut-off mechanisms which activate under unsafe conditions. This provides peace of mind for users, knowing that their safety is prioritized. Additionally, these heaters are designed with portability in mind, allowing for easy movement from one room to another as needed.

One of the key technologies utilized in these models is infrared heating, which warms objects and people directly rather than heating the air. This results in quicker warmth and greater comfort for occupants, making these heaters highly effective in various settings.

Overall, the Desa 050 BTU, TC111 8,000-12, and TC110 8,000-24 represent a blend of efficiency, safety, and user-friendly technology. Whether for home use or in a commercial setting, these heating solutions offer reliability and superior performance, ensuring warm and comfortable spaces during cold weather. With their advanced features and robust construction, users can trust in the durability and efficiency of these heating systems for years to come.