 CAUTION: Do not light at the orifice.

Operating Instructions

Continued

to STOP Heater CAUTION: Do not light at the orifice.

3.Depress the red button on the safety valve admitting gas to the burner (see Figure 6, page 5).

To RESTART HeaterWARNING:Donotdepressred valve button before repeatedly activating the piezo or inserting match.

4.When the gas on the face of the mesh screen lights, continue to hold the valve button depressed for 30 seconds, then release.

5.If flame goes out, wait 5 minutes and repeat the lighting procedure.

6.If heater will not light after repeated tries, do not attempt to repair heater. Return heater to nearest authorized service cen- ter or to manufacturer of this product.

7.For dual burner models, repeat steps 1 through 4 to ignite the other burner.

8.After both burners or single burner, are lit, turn the heater regulator knob to the desired heat setting (LOW, MED, HI).

to STOP Heater

1.Securely close valve on the propane/LP cylinder.

2.Turn the heater regulator knob to the "OFF" position. Wait 15 minutes for the heater to cool down before handling heater.

3.Always remove the heater from the pro- pane/LP tank after each use. Do not store the heater while attached to propane/LP tank. Remove the heater from the pro- pane/LP tank by turning the fuel connector nut clockwise. Always store propane/LP tank outdoors. Never store propane/LP tank in an enclosed area.

To RESTART Heater

1.Securely close valve at propane/LP cylinder.

2.Wait 5 minutes.

3.Restart following To Start Heater proce- dure, page 5.

Maintenance and

Storage

1.Inspect heater before each use. Check connections for leaks. Apply mixture of liquid soap and water to connections. Bubbles forming show a leak that must be corrected. Correct all leaks at once. Have heater inspected at least annually by a qualified service person.

2.Before each use, check the soft "O" ring seat at the bullnose of the POL fitting. If the "O" ring is cut, scuffed, or otherwise damaged, replace it with part number LPA2025.

3.Inspect hose/regulator assembly before each use. If hose is highly worn or cut, replace.

4.Turn off the gas at the propane/LP gas supply cylinder when the heater is not in use.

5.When the heater is to be stored, the connection between the propane/LP gas supply cylinder and the heater must be dis- connected and the cylinder removed from the heater and stored out of doors and in accordance with Chapter 5 of the standard for CAN1-B149 Installation Code.