![OWNER’S MANUAL](/images/new-backgrounds/48203/482035x1.webp)
OWNER’S MANUAL
INTRODUCTION
Model VGL450 series is a radiant heat deco- rative gas appliance that uses a millivolt gas control valve and a pilot ignition system.
This appliance requires a 4"
4"
WARNING: This gas appli- ance must not be connected to a chimney flue servicing a solid fuel burning appliance.
•Model VGL450N uses NATURAL GAS ONLY.
•Model VGL450P uses PROPANE GAS ONLY.
If you have any doubts as to which gas your particular unit is approved and tested for, please check the AGA/CGA rating plate located behind the access panel (Figure 1, page 2).
BEFORE YOU BEGIN
Before beginning the installation of your appliance, read these instructions through completely.
This DESA appliance and its approved com- ponents are safe when installed according to this installation manual and are operated as recommended by DESA. Unless you use DESA approved components tested for this appliance, YOU MAY CAUSE A FIRE
HAZARD!
The DESA warranty will be voided by, and DESA disclaims any responsibility for the following actions :
A)Modification of the appliance or any of the components manufactured by DESA unless otherwise permitted in writing by DESA.
B)Use of any component part not ap- proved by DESA in combination with this DESA appliance.
C)Installation and/or operation in a man- ner other than instructed in this manual.
D)The burning of anything other than the type of gas approved for use in this gas appliance.
This appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/ NFPA 70 or the CSA C22.1 CANADIAN ELECTRICAL CODE for Canada.
The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code ANSI Z223.1 or with the current
This appliance complies with ANS Z21.50- 1998 and CAN/CGA
CAUTION: Installation and re- pair should be done by a quali- fied service person. The appli- ance should be inspected before use, and at least annually by a qualified service person. More fre- quent cleaning may be required due to excessive lint from carpet- ing, bedding material, pet hair, etc. It is imperative that the con- trol compartments, burners and circulating air passageways of the appliance be kept clean.
NOTICE: This appliance is not intended to be used as a primary source of heat.
SELECTING
LOCATION
To determine the safest and most efficient location for your appliance, you must take into consideration the following guidelines:
1.The location must allow for proper clearances (see Clearances, page 4 ).
2.Consider a location where heat output would not be affected by drafts, air con- ditioning ducts, windows or doors.
3.A location that avoids the cutting of joists or roof rafters will make installa- tion easier. Figure 3 shows a plan view of a few common locations.
Flush installations are recommended where living space is limited or at a pre- mium, and since the space required to en- close the appliance would be located be- yond an outside wall, this would also reduce the cutting of joists, roof rafters and such. Check local codes for any restrictions.
Projected installations can extend any distance into the room. A projection may be ideal for a new addition on an existing, finished wall.
Corner installations make use of space that may not normally be used and provides a wider and more efficient range for radiant heat transference.
Internal wall installations provide a dis- creet option for room separation and can also be ideal as an addition to an existing wall.
Also, in selecting a location, the following precautions must be observed:
1.Do not connect this appliance to a chimney system used for a solid fuel burning fireplace.
2.Install in an area providing ventilation and adequate combustion air.
3.Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.
4.NEVER obstruct the front opening of the appliance or the flow of combus- tion and ventilation air. Keep control compartments accessible.
5.Do not locate in the vicinity where gasoline or other flammable liquids may be stored. The appliance area must be kept clear and free from these com- bustible materials.
CORNER
INTERNAL WALLINSTALLATION
INSTALLATION
FLUSH
FULLINSTALLATION PROJECTION
INSTALLATION
Figure 3 - Possible Locations for Installing Appliance
105704 | 3 |