OWNER’S MANUAL
INSTALLATION
Continued
Installing
1.Remove battery cover on back of re- mote control unit.
2.Attach terminal wires to the battery (not included). Place battery into the battery housing. Note: Only use alka- line battery.
3.Replace battery cover onto remote con- trol unit.
Battery
GAS SUPPLY TESTING
Note: This section is intended as a guide for qualified technicians installing gas to this appliance.
Do not connect appliance before pressure testing gas piping. Damage to gas valve may result and an unsafe condition may be caused.
IMPORTANT: The appliance and its indi- vidual
The Gas Control Valve is secured to the burner pan assembly underneath the front
A 1/8" NPT plugged tapping is provided on the Gas Control Valve for a test gauge connection immediately upstream of the gas supply connection to the appliance (see Figure 17).
Red Surface Indicates
For Propane Use Only
Gas Shut |
|
|
|
|
|
| Air Shutter |
Off Valve |
|
|
|
|
|
| |
Coupling |
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
| OFF | PI | W |
|
|
|
|
| L |
|
|
| ||
|
|
| O | AH | TH TP TH |
| |
| IN |
| T | S | TP | ||
|
|
|
| T | |||
| ON |
|
| R | |||
|
| ROB | E | ||||
Flexible |
| PILOT ADJ |
|
|
|
| |
Pilot |
|
|
|
|
| 1/8" NPT | |
Gas Line |
|
|
|
|
| ||
Adjustment |
|
| Plugged | ||||
DO NOT |
|
| |||||
Cap |
|
|
|
|
| Tapping | |
|
|
|
|
|
|
Cover
Remote
ledge.
KINK |
TerminalControl Unit Wires
Battery
Housing
Figure 16 - Installing Battery in Hand- Held Remote Control Unit
Figure 17 - 1/8" Plugged Tapping Location
GAS RATINGS
TYPE OF GAS: | NATURAL | PROPANE/LP |
|
|
|
MAX. INPUT |
|
|
RATING (Btu/hr): | 12,000 | 12,000 |
|
|
|
MANIFOLD |
|
|
PRESSURE: | 3.5 in. W.C. | 10.0 in. W.C. |
|
|
|
* MIN. SUPPLY |
|
|
PRESSURE: | 4.5 in. W.C. | 7.0 in. W.C. |
|
|
|
MAX. SUPPLY |
|
|
PRESSURE: | 10.5 in. W.C. | 13.0 in. W.C. |
|
|
|
*For the purpose of input adjustment
Continued