TOP STUDS MUST

CLEAR SPACERS

ON TOP OF UNIT

22 5/8

397/8

48 1/2

MIN.

Figure 5

1/2

2 MIN. CLEARANCE

MIN. TO

FROM OUTER PIPE

COMBUSTIBLES

TO COMBUSTIBLES

 

 

22 5/8

 

11 5/16

21 1/2

Ø15 OUTER PIPE

 

Figure 8

 

1/2 MIN.

 

OVERLAP

1/2 MIN.

METAL SAFETY STRIPS

 

(SUPPLIED)

 

Figure 6

 

1/2" (12.7mm)

MIN. TO COMBUSTIBLES

NAILING

FLANGES

PREPARED

FRAMING

NAILS OR

SCREWS

Figure 9

Proceed to secure firebox to prepared framing at nail- ing flanges located at the sides of the firebox as shown in Figure 9.

PLATFORM MUST BE

39 7/8

SOLID, FLAT, AND

 

 

FULLY SUPPORTED

 

 

48 1/2

22 5/8

"Z" TYPE

MIN.

 

 

 

METAL

 

 

SAFETY

 

 

SHIELDS

 

 

(NOT

 

 

SUPPLIED)

 

 

 

 

*

 

AS REQUIRED BY DESIGN

 

 

AS LONG AS CEILING

 

Figure 7

CLEARANCE IS

 

MAINTAINED

 

HEARTH EXTENSIONS

A hearth extension is required to protect combustible floor surround- ing firebox. You may fabricate your own per the dimensions shown in Figure 10, page 6.

The hearth extension must project 20 in. min. to the front and 12 in. min. beyond each side of the firebox opening except on the end where projection is 16 in. min. to the front and 20 in. to the sides (see Figure 10, page 6).

55505

5

Page 5
Image 5