Desa (V)VC36P Series Continued, operating optional GWMT1 - Wall Mounted, Thermostat

Models: (V)VC36P Series VC36N, C GCDV36NR, VC36P, C GCDV36PR

1 44
Download 44 pages 34.97 Kb
Page 30
Image 30
Key Pad Lock Feature

OPERATIng fireplace

Continued

Key Pad Lock Feature

This feature allows the user to lock/unlock the keypad on the hand-held remote in the MANU or AUTO mode to prevent inadvertent operation (i.e. children operating the hand-held remote control, etc.). The keypad is locked in either on or off. Press the POWER and LOCK buttons together to turn the unit on or off.

operating optional

GWMT1 - Wall Mounted

Thermostat

operating optional WARNING: Do not con- nect the thermostat to a power source. Electrical shock and/or a fire hazard will occur.

Light the fireplace as instructed in Lighting Instructions on page 27. Set wall thermostat to desired temperature.

This thermostat has been electronically cali- brated at the factory and requires no adjust- ment or leveling.

Upon installation, the thermostat must be al- lowed to stabilize at room temperature for a minimum of 30 minutes for proper operation. To turn the fireplace off, adjust thermostat to the lowest setting and turn the gas control knob back to PILOT. The pilot will remain lit.

IMPORTANT: To turn the pilot off, turn the gas control knob on the heater to the OFF position.

operating optional blower accessory

Locate the blower controls by opening the lower louver panel on the fireplace. Blower controls are located on the right side of the switch bracket to the left just inside the louver panel. The BK manual blower and the BKT thermo- statically-controlled blower have an ON setting and an OFF setting. The blower will only run when the switch is in the ON position. In the OFF position, the blower will not operate.

Note for BKT Only: If you are using BKT blower with optional thermostat (wall mounted or remote control) for the fireplace, your fire- place and blower will not turn on and off at the same time. The fireplace may run for several minutes before the blower turns on. After the heater modulates to the pilot position, the blow- er will continue to run. The blower will shut off after the firebox temperature decreases.

The blower helps distribute heated air from the fireplace. Periodically check the louvers of the firebox and remove any dust, dirt or other obstructions that will hinder the flow of air.

Inspecting Burners

Check pilot flame pattern and burner flame pat- terns often.

pilot assembly

The pilot assembly is factory preset for the proper flame height. Alterations may have occurred dur- ing shipping and handling. Call a qualified service person to readjust the pilot if necessary.

The height of the thermopile must be 3/8" to 1/2" above the pilot flame as shown in Figure 49. The thermocouple must be at a height of about 1/8" above the pilot flame. The flame from the pilot burner must extend beyond both the thermocouple and thermopile.

If you pilot assembly does not meet these require- ments:

turn fireplace off (see To Turn Off Gas to Ap- pliance, page 28)

see Troubleshooting, page 33

Thermopile

3/8" to 1/2"

Thermostat Pilot Burner

operating optional blower accessory 1/8"

pilot assembly•see Troubleshooting, page 33Thermocouple

Piezo

Ignitor

Figure 49 - Pilot Assembly

30

www.desatech.com

116200-01H

Page 30
Image 30
Desa (V)VC36P Series Continued, operating optional GWMT1 - Wall Mounted, Thermostat, operating optional blower accessory