Venting Installation
instructions
Continued
| Vertical Venting |
| V = 40' max. |
Note: Install | Note: Install |
restrictor into | |
restrictor into | inner collar of |
inner collar of | fireplace as |
fireplace as | shown. |
shown. |
|
| 45° |
| Elbow |
45° Elbow
Venting with Two 90° Elbows
Vertical (V1) | Horizontal (H) |
5' min. | 6' max. |
6' min. | 12' max. |
7' min. | 18' max. |
8' min. | 20' max. |
Note: Vertical (V1) + Vertical (V2) = 40' max.
Figure 23 - Vertical Venting
Configuration Using Two 90° Elbows
(Vertical Round High Wind Termination
Shown)
Figure 24 - Vertical Venting Configuration
With No Horizontal Run (Vertical Round
High Wind Termination Shown)
High Altitude Installation
Your
Fireplaces for High Altitude (models ending in
When installing a
When installing this fireplace at an elevation above 4500 feet (in Canada), check with local authorities.
IMPORTANT: For horizontal installations above 2,000 feet, it is recommended that a 12" extension pipe be added before starter elbow (see Figure 25, page 18) and a round horizontal termination be used.
www.desatech.com | 17 |