Table 3. Adjustable Parameters Table (Installer)

Table 3. Adjustable Parameters Table (Installer)

Parameter Name:

Default

Parameter Value Setting

Increment

Installer entry

 

 

 

 

 

System (Go to equipment button and scroll to System) NOTE − All of the following changes are made on the stat.

Equipment Name

 

(keyboard input screen)

 

 

 

 

 

 

 

Filter 1 Timer Selection

Calendar Time

Calendar Time, Run Time

 

 

 

 

 

 

 

Filter 2 Timer Selection

Calendar Time

Calendar Time, Run Time

 

 

 

 

 

 

 

UV Bulb Timer Selection

Calendar Time

Calendar Time, Run Time

 

 

 

 

 

 

 

Humidifier Pad Timer Selection

Calendar Time

Calendar Time, Run Time

 

 

 

 

 

 

 

PureAirt Timer Selection

Calendar Time

Calendar Time, Run Time

 

 

 

 

 

 

 

Smooth Setback Recovery

Enabled

Enabled, Disabled

 

 

 

 

 

 

 

Auto Changeover − Temp Deadband

5ºF

3 to 9ºF

1ºF

 

 

 

 

 

 

Electric Heat Control Mode

Standard

Standard, Even Heat

 

 

 

 

 

 

 

Gas Heat Control Mode: (SLP98, G71MPP)

Load Tracking

Load Tracking Variable Capacity, Variable Capacity, Staged

 

 

 

 

 

 

 

(SL280, EL296)

Staged

Staged only

 

 

 

 

 

 

 

Max Heat Setpoint

90ºF

40 to 90ºF

1ºF

 

 

 

 

 

 

Min Cool Setpoint

60ºF

60 to 99ºF

1ºF

 

 

 

 

 

 

Heat Cool Stages Locked In

Disabled

Enabled, Disabled

 

 

 

 

 

 

 

*1st Stage Differential

1.0ºF

0.5 to 3ºF

0.5ºF

 

 

 

 

 

 

*2nd Stage Differential

1.0ºF

0.5 to 8ºF

0.5ºF

 

 

 

 

 

 

*3rd Stage Differential

0.5ºF

0.5 to 8ºF

0.5ºF

 

 

 

 

 

 

*4th Stage Differential

0.5ºF

0.5 to 8ºF

0.5ºF

 

 

 

 

 

 

*5th Stage Differential

0.5ºF

0.5 to 8ºF

0.5ºF

 

 

 

 

 

 

*6th Stage Differential

0.5ºF

0.5 to 8ºF

0.5ºF

 

 

 

 

 

 

Stage Delay Timers

Enabled

Enabled, Disabled

 

 

 

 

 

 

 

*2nd Stage Delay

20 Minutes

5 to 120 Minutes

5 Min

 

 

 

 

 

 

*3rd Stage Delay

20 Minutes

5 to 120 Minutes

5 Min

 

 

 

 

 

 

*4th Stage Delay

20 Minutes

5 to 120 Minutes

5 Min

 

 

 

 

 

 

*5th Stage Delay

20 Minutes

5 to 120 Minutes

5 Min

 

 

 

 

 

 

*6th Stage Delay

20 Minutes

5 to 120 Minutes

5 Min

 

 

 

 

 

 

*Number of stages shown in thermostat is dependent on equipment that is installed. Electric heat will bring on 2 elements at a time if available.

table continued on next page

Page 37

icomfort Wi-Fit 7−Day Programmable Communicating Thermostat

Page 37
Image 37
Lennox International Inc XC2105, XP2101, XC1702, XP1906, XP1702 Adjustable Parameters Table Installer, Installer entry

FAQ

What is the default stage delay timer setting?

The default stage delay timer setting is 20 minutes.

How many elements will electric heat bring on at a time?

Electric heat will bring on 2 elements at a time if available.

What is the maximum heat setpoint range?

The maximum heat setpoint range is 40 to 90°F.