Lennox International Inc CBX32MV06, XP2101, XC2105, XC1702, XP1906, XP1702, SLP9801, G71MPP03 Tips

Models: CBX40UHV02 EL296V01 CBX32MV06 iComfort Wifi Thermostat SL28003 G71MPP03 SLP9801 XP1702 XP1906 XC1702 XC2105 XP2101

1 72
Download 72 pages 43.71 Kb
Page 69
Image 69

icomfortt enabled Air Handler & conventional non−communicating Air Conditioner

An icomfort air handler (CBX32MV or CBX40UHV) with a conventional non− communicating AC unit.

NOTE − IMPORTANT! Be sure to set up the air handler control for heat strips (if used) prior to powering up the system and thermostat.

1. Configure air handler control (AHC) for auxiliary heat strips if used.

2. Wiring Communicating Indoor / Non−Communicating Out-

door System Wiring diagram on Page 59 and Optional Accessories Wiring (Page 61) for any accessories being installed with the system.

D4−conductor thermostat wire from the icomfort Wi-Fit thermostat to the air handler (R, i+, i−, C)

Dicomfort air handler to conventional AC (5 – 8 wires). (Y1, Y2, C, R, W1,W2)

DWiring as required for accessories

3. On 2−stage AC, cut the

2 Stage Compr" onboard clippable link.

4.On air handler control, remove jumper between W1 & W2 for two−stage electric heat only.

5.After the entire system is wired, power up the system; the icomfort Wi- Fit thermostat will check the system for installed communication de- vices.

6.In the installer setup button, select

ing equipment

yes button.

7.Select the ype" from the device list using the up/down

arrows and press the edit button. Then select the AC type (1−stage AC or 2−stage AC) and press the save button.

8.On the thermostat, go past the

vices" to the o adjust a setting" screen. Select the

device list using the up/down arrows and press the edit button

9.Use the arrows to select

edit. From this Air Handler screen you will have access to the various airflow settings. Set the system air volumes according the needs of the home. When you change certain settings, the system will prompt you to

red settings and press edit. Either make changes or not, but press save either way. The red settings will go away after pressing save. When all CFM settings are complete, press the back button. Press next step to advance to the tests button.

10.Test the system operation and confirm the system is electrically ener- gized and operational. Particularly, test the heat strips (when used) to insure the auxiliary stages have been detected and are operational. Press done.

11.Exit the installer setup mode by selecting the EXIT button.

TIPS

SIf the thermostat fer a choice for

heat" and or the electric heat will not function; the electric heat has not been configured. Configure the electric heat as described on Page 64, or for complete detail, see the Air Handler installation instructions. Re- configure the icomfort system by entering the installer program and se- lecting the setup button and following the prompts.

SIf the thermostat f

choices and does not offer a choice for

non−communicating air conditioning unit. Selectnon− communicating" under the setup button in the Installer Section. Select

Unit Type", press the

edit button and then choose Stage

AC" or tage AC" and press the

save button.

SOn two−stage Air Conditioners you must cut the tage Compr" Link on the air handler control.

Page 69

icomfort Wi-Fit 7−Day Programmable Communicating Thermostat

Page 69
Image 69
Lennox International Inc CBX32MV06, XP2101, XC2105, XC1702, XP1906, XP1702, SLP9801, G71MPP03, SL28003, EL296V01, CBX40UHV02 Tips

FAQ

How do I configure the air handler control for heat strips?

Prior to powering up the system and thermostat, configure the air handler control for auxiliary heat strips if used.

What should I do if the electric heat does not function?

If the electric heat has not been configured, follow the instructions on Page 64 or refer to the Air Handler installation instructions for complete details. Reconfigure the icomfort system as described.

How can I test the system operation?

To test the system operation and confirm that it is electrically energized and operational, use the tests button and specifically test the heat strips when used to ensure the auxiliary stages are detected and operational.