icomfort
The 24VAC icomfort
The icomfort
R i+ i− C Thermostatconnections
BEST PRACTICES! Keep all communication wiring as far away from house electrical wiring and large electrical appliances as possible (15’ [5m] recom- mended).
The thermostat also:
Ssupports three languages (English, French, Spanish),
Ssupports air conditioning units or heat pump units with up to four stages of heat / two stages of compressor operation (2 stages of heat pump heating, 2 stages of auxiliary back−up heating, 2 stages of emergency heating),
Ssupports Indoor Air Quality with
Ssupports variable−capacity / multi−stage heat/cool, universal compati- bility (gas/electric/heat pump/ac), and is dual fuel capable (icomfort− enabled HP only) with two balance points.
Important
RSBus Minimum wire size is 18 gauge
RED
YELLOW
WHITE
GREEN
Maximum total length of all connections on the RSBus is limited to 1500 ft. (450 m). Max. length between compo- nents is 300 ft. (90 m).
Connections to non−communicating outdoor units and accessories are de- scribed in the Quick−Start Installation guide. (Wiring diagrams are also shown beginning on Page 59 of this manual.)
Supports
S | Humidification Measurement and Control, |
S | Dew Point Adjustment Control |
S | Dehumidification Measurement and Control |
S | Humiditrol® Enhanced Dehumidification Accessory (EDA) |
icomfortt−enabled Furnace Control icomfortt−enabled Air Handler Control icomfortt−enabled Outdoor Unit Control
External Sensors − outdoor temperature, discharge air Humidify Control
Dehumidify Control
Note: icomfort
S | |
S | Equipment Maintenance Reminders |
S | Autochangeover Mode −− Permits control of heating, cooling, humidifi- |
| cation, and dehumidification without user involvement. |
Outdoor Temperature Sensor (option)
Figure 1. icomfort by Lennoxt system
Communicating outdoor units contain a built−in outdoor temperature sensor.
Page 3 | icomfort |