Use the Tests / Diagnostics features

Use the Tests / Diagnostics features

NOTE − Test mode lasts for 30 minutes (with the temperature updating every 30 seconds) except for the defrost test, which lasts 30 seconds. Tests fea- ture provides the technician time to manually verify the equipment operation.

The tests feature is available after setup has been completed once. After you press next in the final setup screen, the

ure 18) will appear. (If you want you may skip tests; press skip tests.)

If you re−select the tests button from the full option screen (figure 17), a mes- sage to tart button below to begin system testing" appears. Press

start. The resulting screen will be identical to figure 18.

setup

tests

equipment

alerts

diagnostics

press start button below to begin system testing

start

back

9:39 am Aug 15, 2012

EXIT

Figure 17. Start testing screen

To run all of the tests, press select all. All boxes in the list of tests will be checked. Or, touch box(es) next to test(s) to run certain tests.

After the tests have been started, the screen will describe which test is run- ning and shows a diagnostic summary of each test (see figure 19). After re- viewing the results and concluding that no further tests are needed, press next to proceed to next test. The technician must verify that the test proce- dure is producing the desired result at the equipment.

select tests to run

 

 

Blower

 

 

HP Heat − 1st Stage

 

 

HP Heat − 2nd Stage

 

 

Cooling − 1st Stage

 

 

Cooling − 2nd Stage

select all

 

 

 

Dehumidification

 

 

Gas Heat − Minimum Rate

deselect all

 

Gas Heat − Maximum Rate

start

 

Humidification

 

 

 

 

skip tests

9:39 am Aug 15, 2012

 

 

Figure 18. Select tests to run screen

setup

tests

equipment

alerts

diagnostics

 

current test: Blower

 

 

Check Blower Operation

 

 

Heating Rate

 

 

%

 

Blower CFM Demand

 

1400CFM

 

Blower Off Delay

 

 

Off

 

Blower On Delay

 

 

Off

 

Indoor Blower RPM

 

0

 

Indoor Blower Power

 

0.0000%

 

 

 

 

 

Flame Current

 

 

0.000mA

 

Flame Sense

 

 

 

 

 

No Flame

 

Outdoor Temperature

 

 

 

63ºF

 

 

 

 

 

 

 

 

cancel

next

9:39 am Aug 15, 2012

 

 

 

Figure 19. Typical tests results screens

Page 19

icomfort Wi-Fit 7−Day Programmable Communicating Thermostat

Page 19
Image 19
Lennox International Inc SL28003 Use the Tests / Diagnostics features, Start testing screen, Select tests to run screen

FAQ

What is the duration of the Test mode?

The Test mode lasts for 30 minutes with the temperature updating every 30 seconds, except for the defrost test, which lasts 30 seconds.

When is the tests feature available?

The tests feature is available after the setup has been completed once and the 'tests' button is pressed from the full option screen.

How do I run all of the tests?

To run all of the tests, press 'select all'. All boxes in the list of tests will be checked. Or, touch boxes next to tests to run certain tests.