Table 5. Alert Codes and Troubleshooting

Critical alerts are displayed on Home (user) screen, in the Homeowner alert button, and in the Installer

alert button. Minor and Moderate alerts are found only in the Installer alert button.

 

 

 

Alert

 

 

 

Code

Priority

Alert Text

Steps to clear

 

 

 

 

345

Critical

(Air Handler) The

O relay / Stage 1 failed. Pilot relay contacts did not close or the relay coil did not energize. Replace

 

 

has failed. Either the pilot relay contacts did not

control. Cleared after the fault recovered following reset.

 

 

close or the relay coil did not energize.

 

 

 

 

 

346

Critical

(Air Handler) The heat pump jumper was not

Configuration link(s) not removed on control. Cut O−R. Applicable with non communicating outdoor

 

 

removed on the air−handler control board.

unit with communicating indoor system.

 

 

 

 

347

Critical

(Furnace / Air Handler) The

Operation stopped. Y1 relay / Stage 1 failed. (Pilot relay contacts did not close or

 

 

(furnace or air−handler) has failed. Either the

the relay coil did not energize; no input back to IFC chip). Critical Alert. Cleared after reset and Y1

 

 

pilot relay contacts did not close or the relay

input sensed.

 

 

coil did not energize.

 

 

 

 

 

348

Critical

(Furnace / Air Handler) The

Y2 relay / Stage 2 failed. (Pilot relay contacts did not close or the relay coil did not energize; no input

 

 

(furnace or air−handler) has failed. Either the

back to IFC chip). Critical Alert. Cleared after reset and Y1 input sensed.

 

 

pilot relay contacts did not close or the relay

 

 

 

coil did not energize.

 

 

 

 

 

349

Critical

(Furnace) The

Configuration link R to O needs to be restored. Replace link or hard−wire. Applicable in non commu-

 

 

needs to be restored.

nicating mode. Critical Alert.

 

 

 

 

350

Critical

(Air Handler) The air−handler’s electric heat is

Heat call with no configured or mis−configured electric heat. Check for proper configuring under

 

 

not configured.

Configuring Electric Heat Stages in the air handler installation instructions. Cleared after electrical

 

 

 

heat detection is successful.

 

 

 

 

351

Critical

(Air Handler) There is a problem with the air−

Heat section / Stage 1 failed. (Pilot relay contacts did not close, or the relay coil in the electric heat

 

 

handler’s 1st stage electric heat. Either the pilot

section did not energize.) Air handler will operate on 1st stage for reminder of the heat call. Will clear

 

 

relay contacts did not close, or the relay coil in

after fault recovered.

 

 

the electric heat section did not energize.

 

 

 

 

 

352

Critical

(Air Handler) There is a problem with the air−

Heat section / Stage 2 failed (Same as Code 351).

 

 

handler’s 2nd stage electric heat. Either the pi-

 

 

 

lot relay contacts did not close, or the relay coil

 

 

 

in the electric heat section did not energize. The

 

 

 

air−handler will operate on 1st stage electric

 

 

 

heat until the issue is resolved.

 

 

 

 

 

353

Critical

(Air Handler) There is a problem with the air−

Heat section / Stage 3 failed (Same as Code 351).

 

 

handler’s 3rd stage electric heat. Either the pilot

 

 

 

relay contacts did not close, or the relay coil in

 

 

 

the electric heat section did not energize. The

 

 

 

air−handler will operate on 1st stage electric

 

 

 

heat until the issue is resolved.

 

 

 

 

 

 

 

 

table continued on next page

Page 51

icomfort Wi-Fit 7−Day Programmable Communicating Thermostat

Page 51
Image 51
Lennox International Inc XP1906, XP2101, XC2105, XC1702, XP1702, SLP9801, G71MPP03, SL28003 Alert Codes and Troubleshooting

FAQ

What do critical alerts on the thermostat indicate?

Critical alerts on the thermostat indicate serious malfunctions that require immediate attention. They are displayed on the Home user screen, in the Homeowner alert button, and in the Installer alert button.

How can I clear minor and moderate alerts on the thermostat?

Minor and moderate alerts are found only in the Installer alert button. Follow the steps provided in the Installer alert button to clear these alerts.

How should I handle Code 345 critical alert on the thermostat?

Code 345 indicates that the Air Handler has failed. Pilot relay contacts did not close or the relay coil did not energize. It is a critical alert that can be cleared after the fault recovers following a reset. Consult the manual for further instructions.