Lennox International Inc G71MPP03, XP2101 Other Parameters, Adjustable Parameters Table Installer

Models: CBX40UHV02 EL296V01 CBX32MV06 iComfort Wifi Thermostat SL28003 G71MPP03 SLP9801 XP1702 XP1906 XC1702 XC2105 XP2101

1 72
Download 72 pages 43.71 Kb
Page 42
Image 42
Other Parameters

Table 3. Adjustable Parameters Table (Installer)

Parameter Name

Default

Min.

Max.

Incr.

Dependency

Note

Installer entry

 

 

 

 

 

 

 

 

Other Parameters

Equipment Name

Furnace

N/A

N/A

N/A

None

Up to 35 characters

 

 

 

 

 

 

 

 

 

Continuous Indoor Blower Airflow

DIP SW (See

Min

Max

25

None

1/2 HP blower

 

 

Note 3 at

CFM

CFM

 

 

 

 

 

end of table)

 

 

 

 

 

 

 

Min

Max

25

 

1 HP blower

 

 

 

 

 

 

 

CFM

CFM

 

 

 

 

 

 

 

 

 

 

 

 

Humidification Airflow

Same as

Min

Max

25

Humidifier present

1/2 HP blower

 

 

above

CFM

CFM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Min

Max

25

 

1 HP blower

 

 

 

CFM

CFM

 

 

 

 

 

 

 

 

 

 

 

 

Dehumidification Airflow Percentage

140

(=70%)

120

160

2

OU present and SC

Percent of High Cooling

(=60%)

(=80%)

(=1%)

(Subnet Controller)

Airflow

 

 

 

algorithm support

 

 

 

 

 

 

Note 1: Minimum Outdoor Unit Cooling Stage as a percentage of High Cooling Airflow (value is rounded up to the closest number on 25 CFM resolution.

Note 2: Minimum Outdoor Unit Heating Stage as a percentage of High Heat Pump Airflow (value is rounded up to the closest number on 25 CFM resolution).

Note 3: All communicating Installer Parameters default CFM values based on DIP switch setting (non−communicating value) are calculated using the CFM conversion tables and rounded up to closest number on 25 CFM resolution.

Note 4: Parameter dependency − Certain parameters are dependent on others and may not be shown on the display.

Note 5: Default Values − Jumper/DIP switches impact the default value of some parameters.

506920−01 09/12

Page 42

Page 42
Image 42
Lennox International Inc G71MPP03, XP2101, XC2105, XC1702, XP1906 Other Parameters, Adjustable Parameters Table Installer

FAQ

What are the default values for adjustable parameters?

The default values for adjustable parameters are impacted by jumper/DIP switches and are detailed in the manual.

How can I determine the minimum and maximum airflow values for my thermostat?

The minimum and maximum airflow values for the thermostat are dependent on various factors, including equipment type and setting dependencies. Refer to the manual for specific details.

Where can I find information on the dependency of certain parameters?

The manual includes a note on parameter dependency, providing guidance on parameters that may not be shown on the display due to dependencies.