Lennox International Inc SLP9801, XP2101 Cooling Airflow Settings, Heat Pump Airflow Settings

Models: CBX40UHV02 EL296V01 CBX32MV06 iComfort Wifi Thermostat SL28003 G71MPP03 SLP9801 XP1702 XP1906 XC1702 XC2105 XP2101

1 72
Download 72 pages 43.71 Kb
Page 41
Image 41
Cooling Airflow Settings

Table 3. Adjustable Parameters Table (Installer)

Parameter Name

Default

Min.

Max.

Incr.

Dependency

Note

Installer entry

 

 

Cooling Airflow Settings

High Cooling Airflow (CFM @ 100% cool)

OU tons 400CFM

Min

Max

25

CFM

CFM

 

 

 

 

Min

Max

25

CFM

CFM

 

 

 

 

Outdoor Unit

present

1/2 HP blower

1 HP blower

Low Cooling Airflow (CFM @ lowest

(See Note 1

Min

Max

25

2+ stage Outdoor

1/2 HP blower

 

cool stage)

at end of

CFM

CFM

 

Unit present

 

 

 

 

table)

 

 

 

 

 

 

 

 

Min

Max

25

 

1 HP blower

 

 

 

 

 

 

 

CFM

CFM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Airflow Profile − Cooling

DIP SW

0

3

1

Outdoor Unit

0

A:ON:50%/30s,82% /

 

 

 

 

 

 

present

 

7.5min OFF:50%/30s

 

 

 

 

 

 

 

1

B:ON:82% / 7.5min; OFF:

 

 

 

 

 

 

 

 

No delays

 

 

 

 

 

 

 

2

C:ON: No delays; OFF:

 

 

 

 

 

 

 

 

45sec delay

 

 

 

 

 

 

 

3

D:No delays)

 

 

 

 

 

 

 

 

 

 

Heat Pump Airflow Settings

High Heat Pump Airflow (CFM @ 100%)

OU tons 400CFM

Min

Max

25

CFM

CFM

 

 

 

 

Min

Max

25

CFM

CFM

 

 

 

 

Heat Pump present

1/2 HP blower

1 HP blower

Low Heat Pump Airflow (CFM @

(See Note 2

Min

Max

25

2+ stage Heat Pump

1/2 HP blower

 

lowest stage)

at end of

CFM

CFM

 

present

 

 

 

table)

 

 

 

 

 

 

 

Min

Max

25

 

1 HP blower

 

 

 

 

 

 

 

CFM

CFM

 

 

 

 

 

 

 

 

 

 

 

 

table continued on next page

Page 41

icomfort Wi-Fit 7−Day Programmable Communicating Thermostat

Page 41
Image 41
Lennox International Inc SLP9801, XP2101, XC2105, XC1702, XP1906, XP1702 Cooling Airflow Settings, Heat Pump Airflow Settings

FAQ

What are the default adjustable parameters for cooling airflow settings?

The default adjustable parameters for cooling airflow settings include high cooling airflow CFM, outdoor unit, low cooling airflow CFM and airflow profile.

What is the default high heat pump airflow CFM?

The default high heat pump airflow CFM is 400CFM.

Where can I find more information on the iComfort Wifi Thermostat?

More information on the iComfort Wifi Thermostat can be found on page 41 of this manual.