Lennox International Inc XC1702, XP2101, XC2105 Accessing device to modify, Modify device settings

Models: CBX40UHV02 EL296V01 CBX32MV06 iComfort Wifi Thermostat SL28003 G71MPP03 SLP9801 XP1702 XP1906 XC1702 XC2105 XP2101

1 72
Download 72 pages 43.71 Kb
Page 14
Image 14
Figure 12. Accessing device to modify

Use the up/down arrows to scroll through the device’s settings. The current setting will be displayed on the right−hand side of the screen (figure 12). For example, current value: disabled. Press edit if you want to modify that setting, or press back to return to the previous screen.

Available settings for the devices depend on the installed components. Shown below is an example of enabling and changing the balance point control from default (Disabled) to Enabled. After selecting Enabled, press save to save the changes and return to the previous screen.

The returning screen may appear with the message in red 3, note that two additional items are listed in red. Use the arrows to scroll and highlight each item appearing in red. Press edit, make any desired changes, and press save.

When all affected settings have been edited/saved, the red message disappears. Press back to return to the o adjust a setting ..." screen.

If no more adjustments are necessary, press next to advance to the

run" screen (see Page 19).

System

 

Balance Point Control

 

 

Staged Delay Timers

 

 

2nd Stage Delay

 

current value

3rd Stage Delay

 

Disabled

Balance Point Control

 

 

Humiditrol Comfort Adjust

 

edit

Balance Point Control

Select oneControl Mode

 

 

Min Dehumidification Setpoint

 

reset

OK/HumidDisabledBoundary

Enabled

 

 

 

back

save

cancel

 

System

Staged Delay Timers 2nd Stage Delay 3rd Stage Delay

Lock In 2nd stage HP by Outdoor Temp Balance Point Control

High Balance Point

Low Balance Point

Humiditrol Comfort Adjust

Humidification Control Mode

Min Dehumidification Setpoint

Balance Point Control

 

current value

 

Enabled

 

please view and save all

edit

red settings

 

High Balance Point reset

Range is −17 to 75

Default is 0, inc:1

back

set−to

50

save cancel

Figure 12. Accessing device to modify

Figure 13. Modify device settings

G71MPP or SLP98 Furnace Note:

If your icomfort Wi-Fit thermostat is being used with a G71MPP or SLP98 furnace and is set to variable−capacity mode of operation (the icomfortt default with these units), the thermostat’s settings for stage timers are ignored (even if shown enabled in the thermostat). The stage timer will be used on the cooling side. The furnace software sets and controls the firing rates. The only other controlling factor is the stage temperature differentials. In Load−Tracking Variable Capacity (default for these furnaces), both stage timers and temperature differentials are ignored.

506920−01 09/12

Page 14

Page 14
Image 14
Lennox International Inc XC1702, XP2101 Accessing device to modify, Modify device settings, G71MPP or SLP98 Furnace Note

FAQ

How do I access and modify my thermostat settings?

Use the up/down arrows to scroll through the devices settings. The current setting will be displayed on the righthand side of the screen. Press edit if you want to modify that setting, or press back to return to the previous screen.

What should I do after selecting Enabled for a setting change?

After selecting Enabled, press save to save the changes and return to the previous screen. The returning screen may appear with the message in red, note that two additional items are listed in red. Use the arrows to scroll and highlight each item appearing in red. Press edit, make any desired changes, and press save. When all affected settings have been edited/saved, the red message disappears.

What should I do if the icomfort Wi-Fi thermostat is used with a G71MPP or SLP98 furnace in variable capacity mode?

If your icomfort Wi-Fi thermostat is being used with a G71MPP or SLP98 furnace and is set to variable capacity mode of operation, the thermostat's settings for stage timers are ignored even if shown enabled in the thermostat. The stage timer will be used on the cooling side.