Lennox International Inc XC2105, XP2101, XC1702, XP1906, XP1702, SLP9801 Optional Accessories Wiring

Models: CBX40UHV02 EL296V01 CBX32MV06 iComfort Wifi Thermostat SL28003 G71MPP03 SLP9801 XP1702 XP1906 XC1702 XC2105 XP2101

1 72
Download 72 pages 43.71 Kb
Page 61
Image 61
Optional Accessories Wiring

Optional Accessories Wiring

for use with any icomfort by Lennoxt system

icomfort by Lennoxt

SLP98 & G71MPP FURNACE (IFC) OR AIR HANDLER (AHC)

NOTE: icomfort Wi-Fit THERMOSTAT SENSES HUMIDITY & CONTROLS 24V

PUT) TO CYCLE HUMIDIFIER BASED ON DEMAND. NO OTHER CONTROL OR HUMIDISTAT REQUIRED.

OPTIONAL OUTDOOR AIR SENSOR FOR USE WITH HUMIDIFIER (IF NOT ALREADY IN THE SYSTEM FOR OTHER FUNCTIONS. BUILT INTO ALL icomfort by Lennoxt OUTDOOR UNITS). (SEE OAS NOTE Page 59)

DISCHARGE AIR SEN- SOR (REQUIRED FOR EVEN HEAT) (SEE DAS

For SL290 & EL296, see HUMIDIFIER diagram below (bottom right)

HCWH−01

DEHUMIDIFIER CONTROL

NOTE Page 59)

icomfort Wi-Fit

THERMOSTAT

HVAC for use with any icomfort by Lennoxt systemManual backgroundManual background EQUIPMENT

Rf Cf Gs

HVAC

Gh WDH

EQUIP

NC

 

RSBus

Maximum total length of all connec- tions on the RSBus is limited to 1500ft.

Wire gauge of

RSBus wire is 18.

NOTE: 24V UV LIGHT APPLICATIONS

In an icomfort by Lennoxt system, neither furnace nor air handler transformer will have adequate VA to power 24V UV light applications.

An additional transformer for UV light applications is re- quired. UV light wiring con- nections are independent of HVAC system operation; see UV light installation instruc- tions.

AUXILIARY DEHUMIDIFIER 090 & 135 Manual background capacities only (065 not compatible) Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

icomfort by Lennoxt SL280, EL296 FURNACE

icomfort Wi-Fit thermostat

icomfortt enabled outdoor unit

48G96 Relay

GND

IN

120VAC<−−−−−−−HUMIDIFIER CONNECTIONS−−−−−−> 24VAC

Page 61

icomfort Wi-Fit 7−Day Programmable Communicating Thermostat

Page 61
Image 61
Lennox International Inc XC2105, XP2101, XC1702 Optional Accessories Wiring, for use with any icomfort by Lennoxt system

FAQ

What is the maximum total length of RSBus connections?

The maximum total length of all connections on the RSBus is limited to 1500ft.

Is an additional transformer required for 24V UV light applications in an icomfort by Lennox system?

Yes, an additional transformer for UV light applications is required as neither the furnace nor air handler transformer will have adequate VA to power 24V UV light applications.

Which humidifier capacities are compatible with icomfort by Lennox SL280 and EL296 furnaces?

AUXILIARY DEHUMIDIFIER with 090 and 135 capacities is compatible, while 065 is not compatible.