Troubleshooting

WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater.

CAUTION: Never use a wire, needle or similar object to clean pilot. This can damage pilot unit.

Note: All troubleshooting items are listed in order of operation.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

 

When ignitor button is pressed,

1. Ignitor electrode not con-

1.

Reconnect ignitor cable

there is no spark at pilot

2.

nected to ignitor cable

2.

Free ignitor cable if pinched

 

Ignitor cable pinched or wet

 

 

 

 

by any metal or tubing. Keep

 

3.

Piezo ignitor nut is loose

3.

ignitor cable dry

 

Tighten nut holding piezo

 

 

 

 

ignitor. Nut is located behind

 

4.

Broken ignitor cable

4.

the mounting bracket

 

Replace ignitor cable

 

5.

Bad piezo ignitor

5.

Replace piezo ignitor

 

6.

Ignitor electrode broken

6.

Replace pilot assembly

 

7.

Ignitor electrode positioned

7.

Tighten electrode. Replace if

 

 

wrong

 

necessary

 

 

 

 

 

When ignitor button is pressed,

1. Gas supply turned off or equip-

1.

Turn on gas supply or open

there is spark at pilot but no

 

ment shutoff valve closed

2.

equipment shutoff valve

ignition

2. Gas control knob not in PI-

Turn gas control knob to PILOT

 

3.

LOT position

3.

position

 

Gas control knob not pressed

Press in gas control knob while

 

4.

in while in PILOT position

4.

in PILOT position

 

Air in gas lines when in-

Continue holding down con-

 

 

stalled

 

trol knob. Repeat igniting

 

5. Depleted gas supply (propane/

 

operation until air is removed

 

5. Contact local propane/LP gas

 

6.

LP models only)

6.

company

 

Pilot is clogged

Clean pilot (see Cleaning and

 

 

 

 

Maintenance, page 31) or re-

 

7.

Gas regulator setting is not

7.

place pilot assembly

 

Replace gas regulator

 

 

correct

 

 

 

116236-01E

www.desatech.com

33

Page 33
Image 33
Desa VC42N, CGCDV42NR, VC42P, CGCDV42PR, (V)VC42P, CGCDV42PR Troubleshooting, Observed Problem Possible Cause Remedy

(V)VC42P, CGCDV42PR, VC42N, CGCDV42NR, VC42P, CGCDV42PR specifications

Desa (V)VC42P, CGCDV42PR, VC42N, CGCDV42NR, VC42P, and CGCDV42PR are a range of sophisticated heating solutions that exemplify modern design and efficiency. Designed for residential comfort, these models offer advanced features and technologies that set them apart in the market.

One of the most notable characteristics of these units is their innovative heating technology. They utilize advanced vented and vent-free systems, allowing for flexible installation options based on the needs of the home. These systems efficiently convert fuel into heat, ensuring a high level of warmth with minimal energy consumption. The models cater to various fuel types, including natural gas and propane, allowing consumers to choose the most economical option for their heating needs.

The Desa models are engineered with user-friendly controls, featuring modern thermostats that provide precise temperature regulation. This allows for enhanced comfort and energy efficiency, as users can program the units to operate only when needed. Many of the models come equipped with remote control functionality, offering added convenience for adjusting settings from the comfort of one's sofa.

In terms of safety, these heaters are built with robust safety features such as automatic shut-off systems and oxygen depletion sensors, ensuring that air quality remains safe and that the units operate without risk. This attention to safety is crucial for consumer peace of mind, particularly in homes with children or pets.

Aesthetically, the Desa models shine with an attractive design that complements various interior styles. They are available in multiple finishes and sizes, allowing homeowners to choose a heater that best fits their space and decor. Whether placed in a living room, bedroom, or hallway, these heaters not only provide warmth but also add to the overall ambiance of the home.

Durability is another key characteristic of the Desa series. Constructed with high-quality materials, these heaters promise longevity and reliability. They are designed to withstand the rigors of daily use while maintaining efficiency and effectiveness.

In conclusion, the Desa (V)VC42P, CGCDV42PR, VC42N, CGCDV42NR, VC42P, and CGCDV42PR offer a comprehensive heating solution that combines efficiency, safety, design, and technology. Ideal for modern households, these units represent a smart choice for anyone looking to enhance their home’s comfort and warmth.