Desa (V)VC42P, CGCDV42PR CAUTION: Do not vacuum if pieces are hot, Continued, pilot and burners

Models: (V)VC42P, CGCDV42PR VC42N, CGCDV42NR, VC42P, CGCDV42PR

1 44
Download 44 pages 41.87 Kb
Page 32
Image 32
 CAUTION: Do not vacuum if pieces are hot.

Cleaning and

Maintenance

Continued

pilot and burners CAUTION: Do not vacuum if pieces are hot.

Use only the tempered glass door replacement intended for this fireplace (see Replacement Parts, page 37 for detail on ordering). No substitutions may be made. See Removing/Replacing Glass Door, page 25 for instructions for replacing glass door.

logs WARNING: Do not operate fireplace with the glass door unlatched, removed, cracked or broken.

pilot and burners

Remove ember material before cleaning burners and replace when cleaning is complete.

Burner and controls should be cleaned with compressed air to remove dust, dirt or lint.

Use a vacuum cleaner or small, soft bristled brush to remove excess dust, dirt or lint.

logs

If you remove logs for cleaning, refer to Install- ing Lava Rock and Glowing Embers, page 26, to properly replace logs.

Use a vacuum cleaner to remove any carbon buildup on logs.

Replace log(s) if broken. See Replacement Parts on page 37.

Replace ember material periodically as needed. See Replacement Parts on page 37.

venting system

Conduct annual inspection of the venting system following these guidelines:

1.Check areas of venting system that are exposed to the weather for corrosion (rust spots or streaks and, in extreme cases, holes). Have these items replaced immediately by a qualified service person.

2.Remove the vent cap and shine a flashlight into the vent. Remove any foreign material.

3.Check for evidence of excessive condensation. Continuous condensation can cause corrosion of caps, pipes and fittings and can be caused by having excessive lateral runs, too many elbows or exterior portions of the system being exposed to cold weather.

4.Inspect joints to verify that no pipe section or fitting has been disturbed and loosened. Check mechanical supports such as wall straps for rigidity.

32

www.desatech.com

116236-01E

Page 32
Image 32
Desa (V)VC42P, CGCDV42PR CAUTION: Do not vacuum if pieces are hot, Continued, pilot and burners, logs, venting system