Desa (V)VC42P, CGCDV42PR D E B L, Minimum Clearances for Termination Cap, Inside Corner

Models: (V)VC42P, CGCDV42PR VC42N, CGCDV42NR, VC42P, CGCDV42PR

1 44
Download 44 pages 41.87 Kb
Page 8
Image 8
D

Location of Termination Cap

D

E Inside Corner V

B L Outside Corner

 

C

 

 

Fixed

V

 

Closed

 

 

F

Openable

 

V

 

 

B

 

B

Openable

B

Fixed

Closed

H

V

B

I

V J XG

AM

NN

 

G

 

V

 

G

V K X

V

V TERMINATION CAP

X AIR SUPPLY INLET

G

GAS METER

A

RESTRICTED AREA Balcony with No Side Wall (TERMINATION PROHIBITED)

A= clearance above grade, veranda, porch, deck, or balcony [*12 inches (30.5mc) minimum]

B= clearance to window or door that may be opened

[12 inches (30.5cm) minimum]

C = clearance to permanently closed window [minimum 12 inches (30.5cm) recommended to prevent condensation on window]

D = vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 24 inches (61cm) from the center-line of the terminal [18 inches (45.7cm) minimum]

E= clearance to unventilated soffit [12 inches (30.5cm) minimum]

F= clearance to outside corner (see below)

G= clearance to inside corner (see below)

H= *not to be installed above a meter/regulator assembly within

36 inches (91.4cm) horizontally from the center-line of the regulator

I= clearance to service regulator vent outlet [*72 inches (182.9cm) minimum]

J= clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other fireplace [*12 inches (30.5cm) minimum]

K= clearance to a mechanical air supply inlet [*72 inches (182.9cm) minimum]

L= † clearance above paved side-walk or a paved driveway located on public property [*84 inches (213.3cm) minimum]

M= clearance under veranda, porch, deck [*12 inches (30.5cm) minimum ‡]

N= clearance above a roof shall extend a minimum of 24 inches (61cm) above the highest point when it passes through the roof surface and any other obstruction within a horizontal distance of 18 inches (45.7cm)

† vent shall not terminate directly above a side-walk or paved driveway which is located between two single family dwellings and serves both dwellings*

only permitted if veranda, porch, deck or balconey is fully open on a minimum of 2 sides beneath the floor* * as specified in CAN/CSA B149 (.1 or .2) Installation Codes (1991) for Canada and U.S.A.

Note: Local codes or regulations may require different clearances

Termination Clearances for Buildings with Combustible and Noncombustible Exteriors

Inside Corner

A

V

Outside Corner

Recessed Location

 

 

D

 

 

C

C

A = 6" (15.2cm)

 

E

 

 

V

V

 

B

B = 6" (15.2cm)

 

Balcony with No Side Wall

G

V

G = 12" (30.5cm) minimum clearance

Balcony with Perpendicular Side Wall

H Balcony with Perpendicular Side Wall

V

Figure 7 - Minimum Clearances for Termination CapManual background J

Combustible &

Noncombustible

H = 24" (61cm)

J = 20" (50.8cm)

C = Maximum depth of 48" (121.9cm) for recessed location

D = Minimum width for back wall of recessed location - Combustible - 38" (965mm) Noncombustible - 24" (61cm)

E = Clearance from corner in recessed location- Combustible - 6" (15.2cm) Noncombustible - 2" (5.1cm)

Figure 7 - Minimum Clearances for Termination Cap

www.desatech.com116236-01E

Page 8
Image 8
Desa (V)VC42P, CGCDV42PR installation manual D E B L, Minimum Clearances for Termination Cap, Inside Corner, Outside Corner