INSTALLATION
Continued
6.Install gas connector tube to gas supply fitting. Carefully shape tube to attach to adapter fitting. Be careful not to cause kinks in tube.
7.Test for leaks following instructions under
Testing Burner for Leaks, page 12.
8.Retighten and adjust location of gas control as necessary. Gas control should be level,
Propane/LP Gas Conversion
To convert to propane/LP gas, burner inlet fitting and pilot orifice must be replaced. Propane/LP burner inlet fitting is supplied with orifice installed for a 24" log set. If you have an 18" or 30" set, you must change this orifice also. See Figure 1, page 5 for product identification.
with control rod to front.
9.Install cover to burner pan using screws provided.
10.Install thermocouple, pilot, and ignitor onto valve cover as shown in Figure 11. Use provided screws.
11.Push control rod extension onto “D” shaped control rod through center hole in cover.
12.Install position decal and control knob making sure to align marks with correct stop positions of gas control. Pilot position will allow knob to push in about 1/2". Align decals in pilot position.
Screw Thermocouple
Ignitor
Pilot
Burner Inlet Fitting
1.Remove burner inlet fitting from burner pan assembly. DO NOT remove orifice from this fitting. Propane/LP burner inlet fitting is included in hardware kit (see Figure 12).
2.Be sure to use correct orifice for your ap- pliance. The hardware kit included with this appliance contains two orifices with a
3.For an 18" or 30" set, use a 10 mm socket or nut driver to remove orifice from propane/LP burner inlet fitting. Choose the correct orifice for your log set size and install in place of orifice you just removed.
4.Using thread sealant (resistant to the ac- tion of propane/LP gas) on larger end of fitting, screw burner inlet fitting through hole and into burner manifold (see Figure 13). Tighten using a wrench.
5 . Follow steps 1 through 12 under Natural Gas Installation, page 10.
| Injector for |
Injector | Propane/ |
for Natural | LP Gas |
Gas |
|
NATURAL | PROPANE/ |
GAS | LP GAS |
FITTING | FITTING |
| Figure 12 - Burner Inlet Fittings with | |
Valve Cover | Injectors | |
Piezo Ignitor | Burner Inlet | |
Control Rod | ||
Fitting for | ||
Control Extension | ||
Natural Gas | ||
Knob | ||
| ||
Figure 11 - Installing Cover, Control |
| |
Knob, and Piezo Ignitor |
| |
| Figure 13 - Remove Burner Inlet Fitting |
www.desatech.com | 11 |