Venting Installation
Continued
5.Add next sections of pipe until end penetrates roof line. Check to see that proper clearances are maintained. Extend chimney by adding sections of double wall pipe until pipe is minimum of 30" above highest point of roof cutout. Termination and chimney must extend a minimum of 36" above highest point where it passes through roof.
Flashing installation
Determine the flashing to be used with the roof opening chart. Slide flashing over pipe until base is flat against roof. Replace as many shingles as needed to cover exposed area and flashing base. Secure in position by nail- ing through shingles (see Figure 16). DO NOT NAIL THROUGH FLASHING CONE.
17" Min.
1" Min.
1" Min.
30" Min.
1" Min.
Opening "A"
Installing Flashing on a Metal Roof When installing the flashing on a metal roof, it is required that putty tape be used between the flashing and the roof. The flashing must be secured to the roof using #8 x 3/4" screws and then sealed with roof coating to prevent leak- age through the screw holes. A roof coating must also be applied around the perimeter of the flashing to provide a proper seal.
Storm Collar | Overlap | |
Shingles Top | ||
Flashing | ||
and Sides Only |
Pitch | Slope | Opening | Used Flashing | |
|
| "A" Max. | Model No. | |
Flat | 0° | 17" | ||
26.6° | 19" | |||
6/12- | 45.0° | 24" | ||
12/12 | ||||
|
|
| ||
| Roof Opening 36" Models | |||
19.5" Min. |
| 30" Min. | ||
|
|
| ||
|
| 2" Min. |
| |
|
|
| 2" Min. | |
|
| 2" Min. |
| |
|
|
| Opening "A" |
Cone |
Nail Only
Outer
Perimeter
of Flashing
Underlap Shingles
at Bottom
Figure 16 - Flashing Installation
Storm Collar Installation
Place storm collar over pipe and slide down until it is snug against the open edge of the flashing (see Figure 17). Apply waterproof caulk around the perimeter of the collar to provide a proper seal.
Pitch | Slope | Opening | Used Flashing | |
|
| "A" Max. | Model No. | |
Flat | 0° | 19.5" | ||
26.6° | 22' | |||
6/12- | 45.0° | 27" | ||
12/12 | ||||
|
|
|
Roof Opening 42" and 50" Models
Figure 15 - Roof Opening Measurements
Chimney | Waterproof |
Pipe | Caulk |
Storm | Flashing |
Collar |
Figure 17 - Storm Collar
www.desatech.com | 11 |