Desa (V)JM36, WCM-36J, WCM-42J, WCM-50J Optional Gas Line Installation, Gas Line Access

Models: WCM-36J WCM-50J WCM-42J

1 40
Download 40 pages 9.16 Kb
Page 13
Image 13
Optional Gas Line Installation

Optional Gas Line Installation

Gas line hook up should be done by your supplier or a qualified service person.

Note: Before you proceed, make sure your gas supply is turned off.

Use only a 1/2" black iron pipe and appropri- ate fittings.

1.Remove knockout indentation on refrac- tory or firebrick wall located above refrac- tory hearth floor. Knockout indentation must be firmly tapped with any solid object such as a 1/2" dowel until it is released. Remove fragmented portions of refractory (see Figure 21).

2.Remove gas line cover plate located on either side of fireplace and pull out insula- tion from gas line conduit sleeve. Save insulation for reuse. Replace screws.

3.Run a 1/2" black iron gas line into fireplace through the rear at gas line conduit sleeve (if using a raised platform, add height). Provide sufficient gas line into fireplace chamber for fitting connection (see Figure 22).

Note: Secure incoming gas line to wood framing to provide rigidity for threaded end.

4.Repack insulation around gas line and into sleeve opening. Seal any gaps between gas line and refractory knockout hole with refractory cement or commercial furnace cement, Install the gas appliance or cap-off gas line if desired.

Figure 21 - Gas Line Access CAUTION: All gas piping and connections must be tested for leaks after the installation is completed. After ensuring that the gas valve is on, apply soap and water solution to all connections and joints. Bubbles forming show a leak. Correct all leaks at once. DO NOT USE AN OPEN FLAME FOR LEAK TESTING AND DO NOT OPER- ATE ANYAPPLIANCE IF A LEAK IS DETECTED. LEAK TESTING SHOULD BE DONE BYA QUALI- FIED SERVICE PERSON.

Figure 22 - Gas Line Installation WARNING: Do not operate an unvented gas log set in this fire- place with the chimney removed.

If you install a decorative gas appliance (vented gas log), the decorative gas appliance must comply with the Standard for Decorative Gas Appliance for Installation in Solid Fuel Burning Fireplaces, ANS Z21.60, Z21.84 or RG 2-72and shall also be installed in accor- dance with the National Fuel Gas Code, ANSI 7223NFPA 54 latest edition.

Manual background WARNING: If the fireplace has been used for wood burning, the firebox and chimney must be cleaned of soot, creosote and ashes be a qualified chimney cleaner. Creosote will ignite if heavily heated.

Manual background WARNING: When using a decorative vented gas log, the damper must be removed or per- manently locked in the fully open positionandtheglassdoorsmust be in the fully open position.

Outside of

 

Side

Fireplace

 

Firebrick

 

 

Finished

Gas Line

Remove

Side

Conduit

Knockout

1/2" Dowel

Insulation

 

 

 

Gas

 

 

Conduit

 

Brick with

Cover

 

 

Access

 

 

 

 

Hole

Figure 21 - Gas Line Access

Outside of

 

Side

 

Firebrick

Fireplace

Incoming

Finished

 

Side

Gas Line

1/2" Black

 

Iron Pipe

 

Conduit

 

 

 

 

Seal

 

Repack

Opening

 

with

Provide Enough

Insulation

Refractory

Threaded

 

Cement

End for Fitting

Connection

Figure 22 - Gas Line Installation