Desa WCM-50J Venting Installation, CAUTION Do not seal open, low the installation instructions

Models: WCM-36J WCM-50J WCM-42J

1 40
Download 40 pages 9.16 Kb
Page 12
Image 12
CAUTION: Do not seal open-

Venting Installation

Continued

Terminations/Spark Arrestor

The fireplace system must be terminated with the listed round top or chase terminations. In any case, refer to the installation instructions supplied with the termination.

CAUTION: Do not seal open-

 

ings on the rooftop flashing. Fol-

 

low the installation instructions

 

provided with the termination

24" Min.

being used.

 

18"

Min.

Typ.

 

RTL-10D

Stainless

Level of

Inner Flue

Pipe

Flue Gas

 

Outlet

Secure

 

Termination

 

to Outer

Waterproof

Pipe with 3

Caulking

Screws

Storm

 

 

Collar

 

Flashing

Overlap

 

Shingles (Top

Underlap

and Sides of

Shingles

Flashing Base)

 

Figure 18 - Termination

Chase installations

Instructions for chase installations are included with the chase style termination chosen. In a multiple chase installation, be sure to provide adequate distance between terminations to prevent smoke spillage from one termination to another. We suggest that terminations be separated at least 24", center to center and stacked at a vertical height dif- ference of 18" (see Figure 19).

Note: If a decorative shroud is to be installed, contact the manufacturer for specifications.

24" Min.

Figure 19 - Multiple Chase Installation

10 foot rule

All flue gas outlet chimney terminations must extend a minimum of 3 feet in height above the highest point where it passes through the roof and must be at least 2 feet above the high- est point of the roof that is within a horizontal distance of 10 feet (see Figure 20).

10'

Level of

 

Flue Gas

 

 

 

 

Outlet

 

 

10'

 

2' Min.

3' Min.

 

 

 

 

2' Min.

3' Min.

 

 

Figure 20 - 10 Foot Rule

finishing the fireplace

Combustible materials, such as wallboard, gypsum board, sheet rock, drywall, plywood, etc. may make direct contact with sides and top around the fireplace face. It is important that combustible materials do not overlap the face itself. Brick, glass, tile or other noncombustible materials may overlap the front face provided they do not obstruct essential openings like louvered slots or any other opening. When overlapping with a noncombustible facing material, use only noncombustible mortar or adhesive.

12

www.desatech.com

122273-01A