Desa (V)JM50 SERIES Venting Installation, Continued, Using ELBOW offsets 30E-12DM, Elbow Offset

Models: WCM-36J WCM-50J WCM-42J

1 40
Download 40 pages 9.16 Kb
Page 9
Image 9
Using ELBOW offsets (30E-12DM)

Venting Installation

Continued

if properly locked. It is not necessary to add screws to keep the chimney together (excep- tion, see Figure 10).

Using ELBOW offsets (30E-12DM)

1.To achieve desired offset, you may install combinations of 12", 18", 24", 36" and 48" length of double wall pipe (see offset chart and Figure 10).

2.Chimney weight above offset rests on return elbow. Straps must be securely nailed to rafters or joists (see Figure 11, details A and B).

3.Maximum length of pipe between sup- ports (return elbow or 12S-12DM) is 6' of angle run. Maximum of two 6' angle run sections per chimney system (see Figure 12, page 10).

OFFSET

RISE

 

CHIMNEY LENGTH

 

A

B

12"

18"

24"

36"

48"

4 3/8"

16 3/8"

 

ELBOW SET ONLY

 

9 3/4"

25 1/2"

1

 

 

 

 

 

 

12 3/4"

30 3/4"

 

 

1

 

 

 

 

15"

34 3/4"

 

 

 

1

 

 

 

18"

40"

1

 

1

 

 

 

 

21 1/4"

46 1/4"

 

 

 

 

1

 

 

23 3/4"

49 1/4"

 

 

1

1

 

 

 

27 3/4"

56 3/4"

 

 

 

 

 

 

1

30"

60 3/4"

 

 

1

 

1

 

 

33"

66"

 

 

 

 

 

 

1

36"

71"

 

 

1

 

 

 

1

38 1/4"

75"

 

 

 

 

2

 

 

41 1/4"

80 1/4"

1

 

1

 

1

 

 

45"

86 3/4"

 

 

 

 

2

 

 

46 3/4"

89 1/2"

1

 

1

 

 

 

1

51"

97"

 

 

 

 

1

 

1

53 1/4"

101"

 

 

 

 

2

 

 

56 1/4"

106 1/4"

 

 

 

 

 

 

2

59 1/4"

111 1/2"

 

 

1

 

1

 

1

61 3/4"

115 1/2"

1

 

 

 

 

 

2

64 3/4"

120 3/4"

 

 

1

 

 

 

2

68 1/4"

127"

 

 

 

 

2

 

1

70"

130"

1

 

1

 

 

 

2

74 1/4"

137 1/2"

1

 

 

 

2

 

1

76 3/4"

141 1/2"

 

 

1

 

2

 

1

79 3/4"

146 3/4"

 

 

 

 

4

 

 

OFFSET CHART (22-50 FT. SYSTEM HEIGHT)

4.All pipe connections between the offset and return must be secured with two screws on the outer pipe only (see Figure 10). Do not penetrate the inner stainless.

See Detail A

Figure 11 - Ceiling Support PipeFigure 10 - Elbow Offset 2" Min.

Straps

Detail BStraps

See Detail B

Angle Firestop

 

Straps

Straps

Detail A

Return Elbow

Figure 11 - Ceiling Support Pipe

12S-12DM

Screws

B

A

Figure 10 - Elbow Offset

122273-01Awww.desatech.com

Page 9
Image 9
Desa (V)JM50 SERIES, WCM-36J Venting Installation, Continued, Using ELBOW offsets 30E-12DM, Ceiling Support Pipe 12S-12DM