DeWalt DCN692 Installing and Removing the Battery Pack Fig, Mode Selection, Speed Selection

Models: DCN690 DCN692

1 44
Download 44 pages 53.52 Kb
Page 8
Image 8

Installing and Removing the Battery Pack (Fig. 3)

NOTICE: The contact trip needs to be depressed followed by a trigger pull for each nail followed by

English

NOTE: For best results, make sure your battery pack is fully charged.

To install the battery pack (L) into the tool handle, align the battery pack with the rails inside the tool’s handle and slide it into the handle until the battery pack is firmly seated in the tool and ensure that it does not disengage.

To remove the battery pack from the tool, press the release button (N) and firmly pull the battery pack out of the tool handle. Insert it into the charger as described in the charger section of this manual.

FIG. 3

N

L

a release of both the contact trip and trigger after each nail.

BUMP ACTION (FIG. 6)

Bump action is intended for rapid nailing on flat, stationary surfaces and typically

FIG. 6

 

most effective for applications that require driving shorter nails.

 

When using bump action, two methods are available: place actuation and

 

bump actuation.

 

Slide the selector switch to the right, as shown in Figure 6.

 

To operate the tool using the PLACE ACTUATION method:

WARNING: A nail will fire each time the trigger is depressed as long as the contact trip remains depressed.

1.

Depress the contact trip against the work surface.

2.

Depress the trigger.

NOTICE: Do not store tool with battery pack installed. To prevent damage to the pack and to ensure best battery life, store battery packs out of the tool or charger in a cool, dry location.

FUEL GAUGE BATTERY PACKS (FIG. 4)

 

 

Some DEWALT battery packs include a fuel gauge which consists of

FIG. 4 O

three green LED lights that indicate the level of charge remaining in the

 

 

battery pack.

 

 

 

 

To actuate the fuel gauge, press and hold the fuel gauge button (O). A combination of the three green LED lights will illuminate designating the

level of charge left. When the level of charge in the battery is below the usable limit, the fuel gauge will not illuminate and the battery will need

to be recharged.

NOTE: The fuel gauge is only an indication of the charge left on the

battery pack. It does not indicate tool functionality and is subject to variation based on product components, temperature and end-user application.

For more information regarding fuel gauge battery packs, please call 1-800-4-DEWALT (1-800-433-9258) or visit our website www.DEWALT.com.

Mode Selection

WARNING: Always wear proper eye [ANSI Z87.1 (CAN/CSA Z94.3)] and ANSI S12.6 (S3.19) hearing protection when operating tool.

The DEWALT cordless nailers are assembled in accordance with the ANSI Standard SNT-101-2002. The framing nailer is capable of firing nails using bump actuation or sequential actuation. If you would like to have the bump actuation mode disabled, have the tool serviced by an authorized DEWALT service center. Before operating this tool, look at the selector switch to determine the actuation mode. Read all instructions before selecting actuation mode.

WARNING: Keep fingers AWAY from trigger when not driving nails to avoid accidental firing. NEVER carry tool with finger on trigger. In bump mode tool will fire a nail if contact trip is bumped while trigger is depressed.

SEQUENTIAL ACTION (FIG. 5)

Use sequential action for intermittent nailing where very careful and accurate

FIG. 5

 

placement and depth control is desired. The sequential actuation mode provides

 

the maximum delivery of power for driving the longest nails.

 

To operate the nailer in sequential action mode:

1.Slide the selector switch to the left, as shown in Figure 5.

2.Fully depress nosepiece against the work surface (motor will start).

3.Pull trigger (nail will drive into work surface).

4.Release trigger.

5.Lift nosepiece off work surface.

6.Repeat steps 2 through 4 for next application.

To operate the tool using the BUMP ACTUATION method:

1.Depress the trigger.

2.Push the contact trip against the work surface. As long as the trigger is depressed, the tool will fire a nail every time the contact trip is depressed. This allows the user to drive multiple nails in sequence.

WARNING: Do not keep trigger depressed when tool is not in use. Keep the trigger lock-off in the locked position when the tool is not in use.

WARNING: When the tool’s motor is running, the next actuation, pulling the trigger or depressing the contact trip, will cause a nail to fire.

DRY FIRE LOCK OUT

The nailer is equipped with a dry fire lockout which prevents the tool from actuating when the magazine in nearly empty. When approximately 7 to 9 nails remain in the magazine, the tool ceases to operate. Refer to Loading the Tool to reload a stick of collated nails.

Speed Selection (Fig. 1, 7)

(DCN692 ONLY)

 

 

FIG. 7

This nailer is equipped with a dual speed selection switch (M) located on the

foot.

 

 

 

• For shorter nails, select speed 1 by setting the switch to the left most

 

position.

 

 

 

• For longer nails and more rigorous applications, select speed 2 by

 

setting the switch to the right most position.

 

 

In the event that nails are not driving to depth in speed setting 1, you may

 

have to switch to speed setting 2 for additional driving power.

 

M

NOTICE: Firing nails under 3-inches in length using Speed Setting 2

 

will cause excessive wear to your tool and may result in early failures.

 

 

Suggested Speed Settings

 

 

 

 

 

Application

Typical Nail Length

Speed Setting

 

 

 

 

Framing & Decking

3 1/4", 3 1/2” (8.255 cm, 8.89 cm)

 

2

 

 

 

 

General Framing

3" (7.62 cm)

 

1

 

 

 

 

Sheathing

2 3/8" (6,03 cm)

 

1

 

 

 

 

Fencing

2" (5,08 cm)

 

1

 

 

 

 

8

Page 8
Image 8
DeWalt DCN692, DCN690 instruction manual Installing and Removing the Battery Pack Fig, Mode Selection, Speed Selection