TROUBLESHOOTING GUIDE

MANY COMMON PROBLEMS CAN BE SOLVED EASILY BY UTILIZING THE CHART BELOW. FOR MORE SERIOUS OR PERSISTENT PROBLEMS,

CONTACT A DEWALT SERVICE CENTER OR CALL 1-(800)-4-DEWALT.

WARNING: TO REDUCE THE RISK OF SERIOUS PERSONAL INJURY, ALWAYS DISCONNECT BATTERY PACK FROM TOOL BEFORE ALL REPAIRS

SYMPTOM

CAUSE

FIX

Motor does not run with trigger depressed

Trigger lock in locked position

Unlock trigger lock.

 

Tool is stalled, locking the motor from rotating

Rotate the stall release lever on the tool and the mechanism will release If driver

 

 

blade does not return, remove battery and manually push driver blade back to

 

 

home position.

 

Tool is in the sequential actuation mode

Depress contact trip fi rst before fi ring or switch to bump mode.

 

Tool internal electronics need to be reset

Remove battery, wait 3 seconds and reinsert.

 

Motor stops running after 5 seconds

Normal operation, release trigger and redepress.

 

Terminals are dirty or damaged

See authorized service center.

 

Damaged internal electronics

See authorized service center.

 

Damaged Trigger

See authorized service center.

Motor does not run with contact trip depressed

Trigger lock in locked position

Unlock trigger lock.

 

Dryfi re lock out engaged, blocking contact trip from traveling fully

Load more nails into magazine.

 

Tool is stalled, locking the motor from rotating

Rotate the stall release lever on the tool and the mechanism will release If driver

 

 

blade does not return, remove battery and manually push driver blade back to

 

 

home position.

 

Bent contact trip

See authorized service center.

 

Motor stops running after 5 seconds

Normal operation, release contact trip and redepress.

 

Terminals are dirty or damaged

See authorized service center.

 

Damaged internal electronics

See authorized service center.

 

Damaged Trigger

See authorized service center.

Tool does not actuate (motor runs but will not fi re)

Dryfi re lock out engaged, blocking contact trip from traveling fully

Load nails into magazine.

 

Low battery charge or damaged battery

Check charge level if pack shows state-of-charge Charge or replace battery pack

 

 

if necessary.

 

Jammed nail/drive blade not returned to home position

Remove battery, clear jammed nail, cycle stall release lever, (push driver blade up

 

 

manually if necessary) reinsert battery pack.

 

Damaged driver/return assembly

Replace driver/return assembly See authorized service center.

 

Jammed internal mechanism

See authorized service center.

 

Damaged internal electronics

See authorized service center.

Motor starts up but generates a lot of noise

Jammed nail and driver blade is stuck in down position

Use stall release lever, clear and jammed nails, and return driver blade manually if

 

 

necessary.

 

Damaged driver/return assembly

Replace driver/return assembly See authorized service center.

Drive blade continues to get stuck in down position

Jammed nail and driver blade is stuck in down position

Use stall release lever, clear any jammed nails, and return driver blade manually if

 

 

necessary.

 

Damaged driver/return assembly

Replace driver/return assembly See authorized service center.

 

Debris in nosepiece

Clean nose area and watch closely for small pieces of broken nails stuck in the

 

 

track.

English

13

Page 13
Image 13