DeWalt DPD3100 instruction manual Shutting Down, Solvents, English

Models: DPD3100

1 68
Download 68 pages 12.33 Kb
Page 13
Image 13
Solvents.

4. Verify the filter screen (U) is in water inlet of pump.

The cone side faces out. 5. Connect the cold water source (V) to pump inlet.

NOTE: Water source must provide a minimum of 5 gallons per minute at 20 pSI (138 kPa).

Warning: To reduce the possibility of contami-

U

nation always protect against backflow when con-

 

nected to a potable water system.

 

13.Shutting DownWarning: Risk of unsafe operation. Pull starter grip slowly until resistance is felt. Then pull starter grip (I) rapidly to avoid kickback and prevent hand or arm injury.

Note: Do not allow the starter grip to snap back. Return it gently by hand.

Manual backgroundWarning: Risk of unsafe operation. If engine does not start after two pulls, squeeze trigger of gun to relieve pump pressure. Pull starter cord slowly until resistance is felt. Then pull cord rapidly to

English

6.Connect high-pressure hose (P) to pump outlet.

7.If applying a chemical or cleaning solution, refer to Chemicals and Cleaning

Solvents.

8.Turn the water source on.

Caution: Risk of property damage. Failure to do so could cause damage to the pump.

P

V

avoid kickback and prevent hand or arm injury.

Note: If the oil level in the engine is low, the engine will not start. If the engine does not start, check the oil level and add oil as needed.

14. As the engine warms up, move the choke to

the open position. 15. Depress trigger on gun to start water flow.

Manual backgroundWarning: Risk of unsafe operation. Stand

9.Remove all air from the pump and high pressure hose by depress- ing trigger until a steady stream of water is present.

10.Turn the engine ON/OFF switch (H) to the ON position.

11.Place the fuel valve lever (M) in the ON postion.

12.If the engine is cold, move the choke (K) to the CLOSED position as shown.

on a stable surface and grip gun/wand firmly with both hands. Expect the gun to kickback when triggered.

16. Release trigger to stop water flow.

DANGER: Risk of injury from spray. Engage the

X

trigger lock (X) when gun is not in use to prevent

 

H

M

K

accidental spraying.

17. Adjust spray for the task being performed by changing quick connect nozzle. Refer to Spray Wand Nozzles.

Shutting Down

1.If chemicals were applied, place the chemical hose into a container of clean water and draw clean water through chemical injection system to rinse system thoroughly.

13

Page 13
Image 13
DeWalt DPD3100 instruction manual Shutting Down, Solvents, English