DP

MOUNTING THE CONDENSER

Condenser Installation

1.Select the site for the condenser on the rear or the vehicle sleeper.

2.Hold condenser in the preferred location and mark the holes clearly.

3.Drill holes 17/32” for Nutserts®.

4.Install the condenser assembly in the preferred location.

Mounting Considerations

The condenser must be installed on the back wall of the sleeper (outside). Airflow around the condenser must not be blocked by headache racks, for example.

Install condenser within 8’ of the HVAC.

The condenser must be installed vertically with the blue-marked side on the bottom right (where the liquid refrigerant collects).

Hose connection side of the condenser requires 5” free space to the nearest obstruction to allow for hose connection.

Keep the condenser out of the path of road spray.

Refrigerant hoses must be clamped firmly.

Do not allow Refrigerant hoses to touch each other; heat transfer will occur and change the performance of the HVAC. Insulate or keep the hoses together.

Step Three

Nutserts®

Blue Marking

3/8” NC Bolts

3 Per Side

Min 5” Clearance To

Allow For Hose

Connection

WARNING: If you are installing the condenser to the back wall of the sleeper, use large fender washers or a backing plate for extra support.

NOTE: All hoses, cables, and electrical wiring should be kept safe and secured using split loom and cable ties to prevent abrasion. Stay clear of exhaust pipe and muffler.

Condenser

Refrigerant

Hoses - Clamp

Securely

Condenser 12V

Power Harness

HVAC

Page3

Page 4
Image 4
Diamond Power Products DPS6500 Page3, Step Three, Mounting the Condenser, Condenser Installation, Mounting Considerations