Use these topics to run PortServer TS 8/16 power on self test to validate the PortServer TS 8/16 hardware.

Procedure: Running the POST Using the LEDs

1.Power on the PortServer TS 8/16.

2.Use the following table to interpret the output from the LEDs.

If ...

Then...

 

 

The power LED blinks immediately

A DHCP error has occurred and the

PortServer TS 8/16 was not assigned an

after POST

IP address.

 

 

 

Any of the other four LEDs blink

A hardware component failed.

immediately after POST,

 

 

 

Procedure: Running the POST from a Terminal

1.Connect a terminal to the first serial port on the PortServer 8/16.

2.If the port configuration was changed, configure the terminal to match the port settings. If the port is still using the default configuration, configure the terminal to use the following settings:

VT-100 emulation

9600 baud

8-bit characters

1 stop bit

No parity

3.Reboot the PortServer TS 8/16 and press v when the LEDs begin to blink. POST output appears on the terminal screen.

PortServer TS 8/16 Troubleshooting