Configuring Outbound PPP Connections: Command Line

This section describes how to configure outbound PPP connections. Use it to configure outbound only connections or to configure the outbound portion of bidirectional connections.

Note: CHAP authentication works between two Digi devices. CHAP will be negotiated to PAP for all other connections

Procedure

1.To configure the port for a modem, enter the following command: set ports range=range dev=device

where range is the port or ports and device is one of the following:

mout for outbound only modem connections

mio for bidirectional modem connections.

See the set ports command in the Digi One/PortServer TS Command Reference for more infor- mation.

Example: set ports range=3 device=mout

2.To configure flow control for the ports, enter the following command: set flow range=range flow-control=scheme

where range is the port or ports and flow-control=schemeis the flow control required for this connection. Typically, for modem connections RTS and CTS are on.

Example: set flow range=3 ixon=off ixoff=off rts=on cts=on

See the set flow command in the Digi One/PortServer TS Command Reference for more infor- mation.

3.To configure baud rate for this connection to the modem, enter the following command: set line range=range baud=bps

where range is the port or ports to configure and bps is the line speed in bits-per-second. Typi- cally, you can set this to 115000 bps for modem connections.

Example: set line range=3 baud=115000

4.If you do not want to use the Digi-supplied dialer script (genmdm) and login script (loginscript), which work for most applications, use the set script command to create your own scripts.

See the set script command in the Digi One/PortServer TS Command Reference for more infor- mation.

5.If you do not want to use the Digi-supplied outbound device (gendialer), which works for most applications, enter the following command:

set device name=name ports=ports dialer=name where

name=name is the name for this device

ports are the ports to associate with this device

dialer=name is the name of a dialer script, either the Digi-supplied script or a user-created one

6.To create a PPP user, enter the following command: set user name=name protocol=ppp where name is the name of the PPP user

E xam ple

set user name=pppout protocol=ppp

7.To configure this user for outbound connections, enter the following command:

Configuring PPP

8-5

Page 41
Image 41
Digi 16, TS8 manual Configuring Outbound PPP Connections Command Line

16, TS8 specifications

The Digi TS8 and TS16 are advanced devices within the Digi TransPort series, which are renowned for their versatility in providing robust network connectivity solutions. Designed to cater to the needs of IoT (Internet of Things) applications, these routers are excellent for businesses that require reliable, high-performance communication across various environments.

One of the standout features of the Digi TS8 and TS16 is their cellular connectivity. Both models support multiple cellular bands, including 4G LTE, ensuring that users can maintain a stable and fast internet connection even in remote locations. This makes them ideal for applications like smart grid management, digital signage, and industrial telemetry, where constant connectivity is crucial.

Another significant aspect of the Digi TS8 and TS16 is their dual SIM capability. This feature allows for seamless failover between two cellular networks. In cases where one network experiences an outage, the device automatically switches to the secondary network, thus minimizing downtime and maintaining business continuity. This redundancy is a vital characteristic for mission-critical applications.

The routers also support various WAN technologies, including LTE, Ethernet, and Wi-Fi, providing flexibility for diverse deployment scenarios. With their comprehensive networking capabilities, the Digi TS8 and TS16 can be integrated into existing infrastructures with ease.

In terms of security, these devices offer a robust suite of features designed to safeguard data. They come equipped with advanced firewall capabilities, VPN support, and secure tunneling protocols, ensuring that data transmitted across the network remains protected against unauthorized access.

Additionally, management and monitoring are made easy with Digi’s intuitive web interface and cloud management platform. Users can remotely configure, monitor, and manage their devices, enabling efficient performance tracking and troubleshooting from anywhere in the world.

Both the Digi TS8 and TS16 are built to endure harsh environmental conditions, boasting an industrial-grade design that adheres to rigorous standards. They can operate effectively in extreme temperatures and are resistant to dust and moisture, making them suitable for outdoor and rugged deployments.

Overall, the Digi TS8 and TS16 provide an extensive set of features and characteristics that address the growing demands of modern connectivity. Their reliability, security, and flexible deployment options make them a preferred choice for businesses looking to harness the power of IoT technology. Whether for industrial applications or remote site management, these devices lead the market with their performance and adaptability.