11 Device Information
English
1Type and order code
2Design
2.1Model
2.2Degree of protection according to EN 60 529 for compact devices and heating components
2.3Installation location
3 | Performance data |
|
3.1 | Operating temperature limits: |
|
| Heating water flow/return flow | °C / °C |
| Cooling, flow | °C |
| Air (heating) | °C |
| Air (cooling) | °C |
3.2Temperature spread of heating water at A7 / W35
3.3 Heat output / COP | at | kW / |
| at | kW / |
| at A2 / W35 1 | kW / |
| at A7 / W35 1 | kW / |
| at A7 / W45 1 | kW / |
| at A10 / W35 1 | kW / |
3.4Temperature spread of cooling water at A35 / W7
3.5 | Cooling capacity / COP | at A27 / W7 | kW / | |
|
| at A27 | / W18 | kW / |
|
| at A35 | / W7 | kW / |
|
| at A35 | / W18 | kW / |
3.6 | Sound power level device / outdoors |
|
| dB(A) |
3.7 | Sound pressure level at a distance of 1 m (indoors) | dB(A) |
3.8Heating water flow with an internal pressure differential of 2
m³/h / Pa
3.9Free pressure, heating circulating pump (heating, max. stage)Pa
3.10Cooling water flow with an internal pressure differential of m³/h / Pa
3.11 | Free pressure, circulating pump (cooling, max. stage) | Pa | |
3.12 | Air flow rate with an external static pressure differential of m³/h / Pa | ||
3.13 | Refrigerant; total filling weight |
| type / kg |
3.14 | Output of electric heating element (second heat generator)kW | ||
4 | Dimensions, connections and weight |
| |
4.1 | Device dimensions |
| H x W x L cm |
4.2 | Device connections to heating system | Inch | |
4.3 | Air duct inlet and outlet (min. internal dimensions) | L x W cm | |
4.4 | Weight of the transportable unit(s) incl. packing | kg | |
4.5 | Buffer tank volume |
| l |
4.6 | Buffer tank pressure rating |
| bar |
5 | Electrical Connection |
|
|
5.1 | Nominal voltage; fuse protection |
| V / A |
5.2 | Nominal power consumption 1 | A2 W35 | kW |
5.3 | Starting current with soft starter |
| A |
5.4 | Nominal current A2 W35 / cos ϕ |
| A / |
6Complies with the European safety regulations
7Additional model features
7.1Defrosting
Type of defrosting Defrosting tray included
7.2Heating water in device protected against freezing 4
7.3Performance levels
7.4Controller internal/external
LIK 8MER
| Compact | |
| IP 20 | |
| Indoors | |
| Up to 58 / above 18 | |
| +7 to +20 | |
| ||
| +15 to +40 | |
10.0 |
| |
| 5.0 | |
5.8 / 2.7 |
| 5.5 / 2.6 |
|
| 5.4 / 2.1 |
7.5 / 3.3 |
| 7.4 / 3..2 |
9.3 / 3,9 |
| 9.2 / 3.8 |
|
| 8.8 / 3.2 |
9.8 / 4.1 |
| 9.7 / 4.0 |
7.5 |
| 5.0 |
7.9 / 2.7 |
| 7.9 / 2.6 |
9.6 / 3.2 |
| 9.6 / 3.2 |
7.0 / 2.0 |
| 6.9 / 2.0 |
8.5 / 2.4 |
| 8.5 / 2.4 |
| 53 / 60 | |
| 48.0 | |
0.8 / 2700 |
| |
| 1.6 / 11900 | |
45000 |
| 27000 |
0.8 / 2700 |
| 1.2 / 6500 |
45000 |
| 37000 |
| 2500 / 20 | |
| R404A / 3.3 | |
| 2.0 | |
| 190 x 75 x 68 | |
| G 1'' external | |
| 44 x 44 | |
| 250 | |
| 50 | |
| 6 | |
| 230 / 20 | |
2.27 |
| |
| 2.33 | |
|
|
|
| 30 | |
12.3 / 0.8 |
| |
| 12.7 / 0.8 | |
| 3 |
Automatic
Reverse cycle
Yes (heated)
Yes
1
Internal
1.This data indicates the size and capacity of the system. For an analysis of the economic and energy efficiency of the system, other parameters, such as, in particular, the defrosting capacity, the bivalence point and regulation, should also be taken into consideration. The specified values, e.g. A2 / W55, have the following meaning: External temperature 2 °C and heating water flow temperature 55 °C.
2.The heat circulating pump is integrated.
3.See CE declaration of conformity
4.The heat circulating pump and the heat pump controller must always be ready for operation.