1.3

1Please Read Immediately

1.1Important Information:

ATTENTION!

The device is not suitable for operation with a frequency converter.

ATTENTION!

When transporting the heat pump, ensure that it is not tilted more than 45° (in any direction).

ATTENTION!

The heat pump and the wooden pallet are only joined by the packing film.

ATTENTION!

Do not restrict or block the area around the air intake or outlet.

1.2Legal Regulations and

Directives

The construction and design of the heat pump complies with all relevant EU directives, DIN/VDE regulations (see CE declaration of conformity).

When connecting the heat pump to the power supply, the rele- vant VDE, EN and IEC standards are to be fulfilled. Any further connection requirements stipulated by local utility companies must also be observed.

When connecting the heating and/or cooling system, all applica- ble regulations must also be adhered to.

Persons, especially children, who are not capable of operating the device safely due to their physical, sensory or mental abilities or their inexperience or lack of knowledge, must not operate this device without supervision or instruction by the person in charge.

Children must be supervised to ensure that they do not play with the device.

English

ATTENTION!

In the case of large-volume heating circuits, an additional expansion vessel must be used to supplement the installed expansion vessel (24 litres, 1.0 bar admission pressure).

ATTENTION!

Never use cleaning agents containing sand, soda, acid or chloride as these can damage the surfaces.

ATTENTION!

We recommend the installation of a suitable corrosion protection system to prevent the formation of deposits (e.g. rust) in the condenser of the heat pump.

ATTENTION!

Before opening the device, ensure that all circuits are isolated from the power supply.

ATTENTION!

Work on the heat pump may only be carried out by authorised and qualified after-sales service technicians.

1.3Energy-Efficient Use of the

Heat Pump

With the purchase of this heat pump you are helping to protect the environment. A prerequisite for energy-efficient operation is the correct design of the heat source system and heating (radia- tors and circulation pump) or cooling system.

It is particularly important for the efficiency of a heat pump to keep the temperature difference between heating water and heat source as small as possible. For this reason, it is advisable to de- sign the heat source and heating system very carefully. A tem- perature difference of approx. one Kelvin (1 °C) increases the power consumption by around 2.5 %. When designing the heating system, it should be borne in mind that special consum- ers such as e.g. hot water preparation should also be considered and dimensioned for low temperatures. Underfloor heating systems (panel heating) are optimally suited for heat pump use on account of the low flow temperatures (30 °C to 40 °C).

It is important to ensure that the heat exchangers are not con- taminated during operation because this increases the tempera- ture difference, in turn reducing the COP.

Correct adjustment of the heat pump controller is also important for energy-efficient use of the heat pump. Further information can be found in the heat pump controller's operating instructions.

The heat pump is equipped with an overflow mechanism to pre- vent very low flow rates in the heat pump.

The installed buffer tank increases the amount of water in the heating circuit and guarantees reliable defrosting.

www.dimplex.de

E-2

Page 3
Image 3
Dimplex LIK 8MER manual Please Read Immediately, Important Information, Legal Regulations Directives

LIK 8MER specifications

The Dimplex LIK 8MER is a cutting-edge electric radiator that combines modern technology with stylish design. Designed to provide efficient warmth and comfort in residential settings, this heating solution stands out for its user-friendly features and high performance.

One of the main characteristics of the LIK 8MER is its advanced electronic control system, which promotes efficient energy usage. This system allows for precise temperature management, ensuring that your living space remains comfortable without excessive energy consumption. The radiator can be programmed to suit your lifestyle, with options to set different temperature levels for various times of the day or week.

The LIK 8MER is equipped with Dimplex’s unique Duo Heat technology, which enhances heat distribution throughout the room. This technology combines convection heating and thermal storage, allowing the radiator to store heat and release it gradually, ensuring consistent warmth. As a result, users experience a more stable and comfortable environment, devoid of the cold drafts often associated with traditional heating systems.

Another key feature of the Dimplex LIK 8MER is its sleek design. The radiator's minimalist aesthetic allows it to seamlessly integrate into any home décor, making it an attractive addition to both modern and traditional interiors. Available in various sizes, the LIK 8MER can easily fit in different spaces, whether it’s a living room, bedroom, or hallway.

In terms of safety, the LIK 8MER is designed with multiple features to ensure peace of mind for users. It includes overheat protection, which automatically turns off the radiator if it gets too hot, preventing any risk of fire. Furthermore, its surface temperature is kept at safe levels, making it suitable for homes with children or pets.

Additional technologies include a built-in timer and an intelligent learning function. The timer allows users to set the radiator to turn on or off according to their schedule, while the learning function adapts to the user’s habits, optimizing energy use based on past behavior.

Overall, the Dimplex LIK 8MER electric radiator is a perfect blend of technology, efficiency, and style. Its innovative features and thoughtful design make it a practical choice for anyone seeking to enhance their home heating experience. Whether you are aiming to save on energy bills or simply seeking reliable warmth, the LIK 8MER delivers on all fronts.