SECTION 1 - INSTALLATION
Prior to beginning the installation of the slide gate operator, we suggest that you become familiar with
the instructions, illustrations, and wiring guide-lines in this manual. This will help insure that your
installation is performed in an efficient and professional manner.
The proper installation of the vehicular slide gate operator is an extremely important and integral part
of the overall access control system. Check all local building ordinances and building codes prior to
installing this operator. Be sure your installation is in compliance with local codes.

1.1 Specifications

Class of Operation: Class I, II, III, IV
Type of Gate: Vehicular Slide Gates Only
Horsepower: 1/2 HP and 1 HP
Voltage: 1/2 HP: 115, 208, 230, 460
1 HP: 115 – 230 1Ø, 208 / 230 / 460 3Ø
Current: Varies with voltage and phase. See page 22.
Max Gate Weight1: 1000 Lbs. (1/2 HP)2, 1500 Lbs. (1 HP)2
Max Gate Length1: 30 Ft. (1/2 HP), 45 Ft. (1 HP)
Cycles / Hr: 60/Hr
Speed: Approximately 1 Ft./Sec.
Entrapment Protection: Primary – Inherent (Type A)
Secondary – Provision for connection of a non-contact
sensor (Type B1) and/or a contact sensor (Type B2).
Secondary entrapment protection devices are not supplied
with the operator and must be ordered separately.
Note 1: Assumes gate is in good working condition installed on a
level surface.
Note 2: Operators with Convenience Open Option
800 Lbs. (1/2 HP), 1300 Lbs. (1 HP)
28.5 (1 HP)
27.5
16.5
11
21.5 (1/2 HP)
9310-065-E-5-07 Page 17