Mount operator to pad using 3/8 or 1/2 sleeve anchors.
See page 18-19.
1
2Attach chain. Adjust chain to allow approximately 1-inch of sag per 10-feet of gate width.
Be sure to remove the pin from the breather plug.
See page 20-21.
3Connect supply voltage as described in section 2.1. Be sure power is OFF!
See page 26.
4Connect control wiring as shown. Radio receiver connects to terminals 1-2-3. Full open
input devices connect to terminals 4 and 13. Partial open input devices connect to
terminals 5 and 13. Terminals 1 and 13 are the same - 24 volt common.
5Connect secondary entrapment prevention devices.
See page 27.
6Connect in-ground loop wires to REVERSE and EXIT loop detectors as required.
See page 28.
7Set close timer ON or OFF (SW-1, switch 2) as required. If gate system does not utilize in-
ground loop system or photo-cells, timer must be OFF.
See page 34-35.
8Push gate to open position. Adjust OPEN limit nut to activate open limit switch. Push gate
closed. Adjust CLOSE limit nut to activate close limit switch.
See page 36.
9Turn power ON. Give gate an open command. If gate runs towards CLOSE position, turn
power off. Change setting of direction switch (SW-1, switch 1) and then turn power ON.
Give gate an open command. Adjust limit nuts as necessary.
See page 36.
10 Adjust both open and close inherent reverse sensitivity. NOTE: Operator will assume a
"soft shutdown" during sensitivity adjustments. This will require operator open input to be
activated to resume normal operation.
See page 37.
QUICK START
Page 4 9310-065-E-5-07