2.5 Primary – Secondary (Bi-parting) Gate Wiring
The interface wiring between the two operators requires six (6) wires (18 AWG minimum) for control
and secondary entrapment protection device connection. Each operator must be connected to it's
own power source as described in section 2.1. Be sure that both operators are wired to the same
phase in the breaker panel. Check at the breaker panel by measuring voltage from HOT to HOT.
This should read 0 volts. If the meter reads 230 Volts, change the wiring.
4403-010
Circuit Board
Secondary Entrapment
Protection Inputs
DOORKING, INC., INGLEWOOD, CA 90301
Title:
Date: Rev.Dwg. No.
4403-010
Circuit Board
Secondary Entrapment
Protection Inputs
Common
Relay
Power
Exit Loop
Reverse Loop
Reverse Loop
DoorKing
9409-010
TB1 TB2 TB3
Conduit
Primary
Operator Secondary
Operator
Yellow
Violet
Brown
Orange
Green
Green
Yellow
Violet
Brown
Orange
A B C
AOpen direction non-contact sensor - Primary Operator.
COpen direction non-contact sensor - Secondary Operator.
BClose direction non-contact sensor - Both Operators.
Open direction contact sensor - Secondary Operator.
E
DOpen direction contact sensor - Primary Operator.
D E
D E
1Connect the Primary / Secondary interconnection wiring as shown. Wire colors are based
on DoorKing interconnection cable (P/N 2600-75x).
Place a jumper from terminal 2 to terminal 4 in the PRIMARY operator only.
Set SW 1, Switch 3 to the OFF position in the PRIMARY operator.
Plug a two-channel (P/N 9409-010) loop detector into the OPEN loop port in the
PRIMARY operator. Connect loops and loop detector as shown.
Connect radio receiver as shown. If partial open feature is desired with radio receiver,
connect receiver relay to terminal 5. Connect other OPEN devices to terminal 4 (Full
Open) or terminal 5 (Partial Open) as required.
Connect standard reverse devices to terminal 6 and/or connect secondary non-contact
and/or contact sensors to Secondary Entrapment Protection inputs as shown.
2
3
4
5
1
2
3
4
5
5 5
6Connect chassis ground to chassis ground.
6 6
7/07 A
4403-DUAL-1
Model 9310
Primary / Secondary Wiring Diagram
19 201234567891011121314
15 16 17 18
19 201234567891011121314
15 16 17 18
Open Photo
Close Photo
Open Edge
Close Edge
Common
Common
Open Photo
Close Photo
Open Edge
Close Edge
Common
Common
Page 30 9310-065-E-5-07