UL 1610 and 1076 SPECIFICATIONS

Installation

UL 1610 and 1076 SPECIFICATIONS

Central-Station and Proprietary Burglar-Alarm Units

17.1Opening/Closing reports

The Opening/Closing Reports option must be programmed as YES. See section 5.2 of the XR10 Programming Guide (LT-0230) and XR20 Programming Guide (LT-0305).

17.2Automatic bell test

This option must be programmed as YES. See section 7.3 of the XR10 Programming Guide (LT-0230) and XR20 Programming Guide (LT-0305).

17.3Proprietary dialer

The Model XR10/XR20 provides Grade A proprietary service when configured as a digital dialer.

UL 1635 SPECIFICATIONS

Digital Burglar Alarm Communicator System Units

18.1Digital Dialer telephone number

Both programmed telephone numbers must begin with a D or P. See sections 3.17 and 3.18 of the XR10 Programming Guide (LT-0230) and XR20 Programming Guide (LT-0305).

18.2Entry delay

The maximum entry delay used must not be more than 60 seconds. See section 6.4 of the XR10 Programming Guide (LT-0230) and XR20 Programming Guide (LT-0305).

18.3Exit delay

The maximum exit delay used must not be more than 60 seconds. See section 6.5 of the XR10 Programming Guide (LT-0230) and XR20 Programming Guide (LT-0305).

18.4Test frequency

The Test Frequency option must be programmed so that the XR10 sends a report once every 24 hours. See section 3.6 of the XR10 Programming Guide (LT-0230) and XR20 Programming Guide (LT-0305).

18.5Automatic bell test

This option must be programmed as YES. See section 7.3 of the XR10 Programming Guide (LT-0230) and XR20 Programming Guide (LT-0305).

18.6Grade B Central Station

Grade B Central Station service can be provided under UL 1635 by adding a Grade A local audible signal appliance and placing the Model XR10/XR20 panel into the Model 349A Grade A Attack Resistant Housing.

UL 365 and 609 SPECIFICATIONS

Police Station Connected and Local Burglar Alarm Units and Systems

19.1Entry delay

The maximum entry delay used must not be more than 60 seconds when using the Model 349A Grade A housing. See section 6.4 of the XR10 Programing Guide (LT-0230) and XR20 Programming Guide (LT-0305).

19.2Grade A bell

A Grade A local audible signal appliance must be used.

19.3Bell cutoff

The bell cutoff time cannot be less than 15 minutes. See section 7.2 of the XR10 Programming Guide (LT-0230) and XR20 Programming Guide (LT-0305).

19.4Automatic bell test

The Automatic Bell Test option must be programmed as YES. See section 7.3 of the XR10 Programming Guide (LT-0230) and XR20 Programming Guide (LT-0305).

19.5Grade A Mercantile

For Grade A Mercantile and Police Station Connect operation the Model XR10/XR20 must be mounted in a Grade A attack resistant housing, (DMP Model 349A).

XR10/XR20 Installation Guide