UNIVERSAL UL BURGLARY SPECIFICATIONS

Installation

UNIVERSAL UL BURGLARY SPECIFICATIONS

15.1Introduction

The programming and installation specifications contained in this section must be completed when installing the XR10/XR20 panel in accordance with any of the UL burglary standards. Additional specifications may be required by a particular standard.

15.2Wiring

All wiring must be in accordance with NEC, ANSI/NFPA 70, UL 681, and UL 611 for all burglary installations.

15.3Police station phone numbers

The digital dialer telephone number programmed for communication must not be a police station phone number, unless that phone number is specifically provided for that purpose.

15.4Bypass reports

The bypass reports option must be programmed as YES for all UL burglary applications. See section 5.5 of the XR10 Programming Guide (LT-0230) and XR20 Programming Guide (LT-0305).

15.5System maintenance

Proper installation and regular maintenance by the installing alarm company and frequent testing by the end user is essential to ensure continuous satisfactory operation of any alarm system. Offering a maintenance program and acquainting the user with the correct procedure for use and testing of the system is also the responsibility of the installing alarm company.

15.6Cross zoning

Zones used for cross zoning must be installed to allow detection of the same event. Cross zoning shall not conflict with UL 681 or 1641.

15.7Ground Start

Ground Start phone lines must not be used for UL listed systems.

15.8UL Listed Receivers

UL has verified operation with the DMP SCS-1 Security Receiver, Sur-Gard SG-HLR2-DG, FBII CP220PB, Osborne-Hoffman Quick-Alert and Radionics D6500 receivers.

UL 1023 SPECIFICATIONS

Household Burglar-Alarm System Units

16.1Bell cutoff

The bell cutoff time cannot be less than five minutes. See section 7.2 of the XR10 Programming Guide (LT-0230) and XR20 Programming Guide (LT-0305).

16.2Entry delay

The maximum entry delay used must not be more than 45 seconds. See section 6.4 of the XR10 Programming Guide (LT-0230) and XR20 Programming Guide (LT-0305).

16.3Exit delay

The maximum exit delay used must not be more than 60 seconds. See section 6.5 of the XR10 Programming Guide (LT-0230) and XR20 Programming Guide (LT-0305).

16.4 Zone expansion on 4-wire bus

When expansion zones are used, the keypad and zone

Normally Closed

expander 4-wire bus must be limited to three feet in length

unless an external communication fail indicator is added. A

12 VDC relay may be wired as a communication fail

indicator. To install, connect the negative side of the

indicator to one of the panel's annunciator outputs and the

positive side to the smoke power (terminal 11 of the XR10/

Voltage output

+

from terminal 11

 

Zone activated

annunciator output

 

Voltage output

+

from terminal 11

 

 

1k Ohm

Common

Normally Open

XR20 panel). See section 7.5C of the XR10 Programming

Guide (LT-0230) and XR20 Programming Guide (LT-0305).

Zone activated

annunciator output

 

Device Fail LED

In addition to the wiring described above, a 24 hour zone must be programmed to activate the appropriate annunciator output.

XR10/XR20 Installation Guide