Installation
UNIVERSAL UL BURGLARY SPECIFICATIONS
15.1Introduction
The programming and installation specifications contained in this section must be completed when installing the XR10/XR20 panel in accordance with any of the UL burglary standards. Additional specifications may be required by a particular standard.
15.2Wiring
All wiring must be in accordance with NEC, ANSI/NFPA 70, UL 681, and UL 611 for all burglary installations.
15.3Police station phone numbers
The digital dialer telephone number programmed for communication must not be a police station phone number, unless that phone number is specifically provided for that purpose.
15.4Bypass reports
The bypass reports option must be programmed as YES for all UL burglary applications. See section 5.5 of the XR10 Programming Guide
15.5System maintenance
Proper installation and regular maintenance by the installing alarm company and frequent testing by the end user is essential to ensure continuous satisfactory operation of any alarm system. Offering a maintenance program and acquainting the user with the correct procedure for use and testing of the system is also the responsibility of the installing alarm company.
15.6Cross zoning
Zones used for cross zoning must be installed to allow detection of the same event. Cross zoning shall not conflict with UL 681 or 1641.
15.7Ground Start
Ground Start phone lines must not be used for UL listed systems.
15.8UL Listed Receivers
UL has verified operation with the DMP
UL 1023 SPECIFICATIONS
Household Burglar-Alarm System Units
16.1Bell cutoff
The bell cutoff time cannot be less than five minutes. See section 7.2 of the XR10 Programming Guide
16.2Entry delay
The maximum entry delay used must not be more than 45 seconds. See section 6.4 of the XR10 Programming Guide
16.3Exit delay
The maximum exit delay used must not be more than 60 seconds. See section 6.5 of the XR10 Programming Guide
16.4 Zone expansion on |
When expansion zones are used, the keypad and zone |
Normally Closed
expander |
unless an external communication fail indicator is added. A |
12 VDC relay may be wired as a communication fail |
indicator. To install, connect the negative side of the |
indicator to one of the panel's annunciator outputs and the |
positive side to the smoke power (terminal 11 of the XR10/ |
Voltage output | + |
from terminal 11 |
|
Zone activated | – |
annunciator output |
|
Voltage output | + |
from terminal 11 |
|
| 1k Ohm |
Common
Normally Open
XR20 panel). See section 7.5C of the XR10 Programming |
Guide |
Zone activated | – |
annunciator output |
|
Device Fail LED
In addition to the wiring described above, a 24 hour zone must be programmed to activate the appropriate annunciator output.
XR10/XR20 Installation Guide
2841 E. Industrial Drive Springfield, MO
Page 11