Installation
4.2Mounting keypads
Security Command keypads have removable covers that allow you to easily mount the base with keypad circuit board to a wall or other flat surface using the screw holes provided on each corner. Before mounting the base, connect the keypad wire harness leads to the
For mounting keypads on solid walls, or for applications where conduit is required, use a DMP 775, 776, or 778 keypad conduit backbox.
4.3Wiring keypads
Keypad data bus
The keypad data bus consists of a
Refer to the wiring diagram in this guide for additional wiring information. See section 3.2.
Primary Power Supply
5.1AC terminals 1 and 2
Connect the transformer wires to terminals 1 and 2 on the panel. Use no more than 70 ft. of 16 gauge, or 40 ft. of 18 gauge, wire between the transformer and the XR10/XR20.
Always ground the panel before applying power to any devices: The XR10/XR20 must be properly grounded before connecting any devices or applying power to the panel. Proper grounding protects against Electrostatic Discharge (ESD) that can damage system components. See Earth ground, section 6.2.
5.2Transformer types
The standard transformer for the XR10/XR20 is 16.5 VAC 40VA, which provides up to 500mA of auxiliary current and 100mA of smoke detector output. You can use either the Model 320
The transformer must be connected to a 120 VAC 60 Hz commercial power outlet that is not controlled by a wall switch. Never share the transformer output with any other equipment.
Secondary Power Supply
6.1Battery terminals 3 and 4
Connect the black battery lead to terminal 4 on the panel and to the negative terminal of the battery. The negative terminal connects to the enclosure ground internally through the XR10/XR20 circuit board. Connect the red battery lead to terminal 3 on the panel and to the positive terminal of the battery. Observe polarity when connecting the battery. The XR10 and XR20 panels can charge up to two batteries.
Use sealed
GEL CELL BATTERIES CANNOT BE USED WITH THE XR10/XR20 PANEL.
6.2Earth ground
Terminal 4 of the XR10/XR20 panel must be connected to earth ground using 14 gauge or larger wire to provide proper transient suppression. DMP recommends connecting to a metal cold water pipe or ground rod only. Do not connect to electrical conduit or a telephone company ground.
6.3Replacement period
DMP recommends the battery be replaced every 3 to 5 years under normal use.
XR10/XR20 Installation Guide