Introduction
Panel Specifications
1.1Power supply
Transformer Input: 16.5 VAC 40VA (Models 320
Standby Battery: 12 VDC 6.5Ah (40VA transformer charges up to 2 batteries)
Auxiliary Output: 12 VDC at 500mA
Bell Output: 12 VDC at 1.5 Amps
Smoke Detector Output: 12 VDC at 100mA All circuits inherent power limited
1.2Communication
1.3Panel zones
Nine 1k Ω EOL burglary zones (zones 1 to 9)
One 3.3k Ω EOL Class B powered fire zone with reset capability (zone 10)
1.4Keypads
You can connect up to four of the following supervised keypads to the XR10/XR20 panels.
•16 or 32 character alphanumeric keypads
•
In addition, the following zone expanders can be added to the XR20 panel:
•Four and single point zone expanders
•Single point PIR and glassbreak detectors
When using the FA426 Wireless Receiver, the XR20 allows unsupervised devices to be added to address five.
1.5Outputs
The XR10/XR20 panels provide four open collector outputs rated for 50mA each. See section 12.1. A Model 300 Wire Harness is required. Open collectors don't provide voltage but instead ground a positive voltage source.
1.6Enclosure specifications
The XR10/XR20 ship in an enclosure with EOL resistors, battery leads, user's guide, and programming sheet.
Size: | 12.5" W x 9.5" H x 2.75" D |
Weight: | 4 lbs |
Color: | Gray or Black |
Construction: | 20 gauge cold rolled steel |
Introduction
2.1Description
The DMP XR10/XR20 Command Processors are powerful 12 VDC burglary and fire communicator panels with battery backup. The XR10/XR20 provide nine
2.2System configurations
The XR10/XR20 can be programmed to operate as either an All/Perimeter system that provides one Perimeter area and one Interior area, or as a Home/Sleep/Away system that provides one Perimeter, one Interior, and one Bedrooms area. The Bedrooms area can include any protection devices the user wants disarmed during their sleeping hours and armed in the Away mode. In addition, the XR20 can operate as a four area system.
XR10/XR20 Installation Guide
2841 E. Industrial Drive Springfield, MO
Page 1