STEP 3 | Enter the original value which displayed in | CURRENT=*.***A | |
| the VFD or enter a new value by using |
|
|
| number keys or Rotary knob to adjust the |
|
|
| voltage value |
|
|
|
|
|
|
STEP 4 | Press Enter to confirm | 0.000V | *.***A |
Setup the input current at 4.33A.
Method 1: To set up by using number keyboard
Step1. Press | button. | |
|
Step2. Press numeric button to enter the current value 4.33.
Step3. Press | Enter | button to confirm the current value. | |
| |||
Method 2: To set up | by using Rotary SW |
(1)If the key board is unlocked by password, directly adjust the Rotary SW button, and voltage will be continually changed from the previews value according the rotation. At the beginning, the cursor will be shown on the last number of the value which is indicated on the VFD, you can move the cursor to the first number, second number etc by using number buttons, and then adjust the Rotary SW to change each number, and let it stay at *.** A. Please see the following description. Then press
0.00A 0.00V
0.0W 4.33A
Procedure:
Step1. Press | button, |
Step2. Adjust the Rotary knob to change the value, the operation is as the same as item (1) Step5. Press Enter button to confirm the current value.
P-set (set up a constant power from 0 to Max power)
8500 series electronic load can be set up for a constant power. Constant power setup procedure is as following:
| Procedure |
|
| Operation details |
| VFD display |
| Step 1 |
| Press |
| POWER =0.000W | |
| Step 2 |
| Enter a new value by using numeric keys or |
| POWER=*.***W | |
|
| Rotary knob to adjust the voltage value |
| |||
|
|
|
|
| ||
|
|
|
|
|
|
|
| Step 3 |
| Press | Enter to confirm. |
| 0.000W P:*.000W |
R-set (set up a constant resistance from 0.1Ω to 4000Ω)
8500 series electronic load can be setup for a constant resistance. Constant resistance setup procedure is as following:
Procedure
Operation details
VFD display
27