Page 1
Image 1
INSTRUCTION
MANUAL
MODEL 8510
Model 8510 600W Programmable DC Electronic Load
1
Page 1
Page 2
Page 1
Image 1
Page 1
Page 2
Contents
Instruction Manual
Programmable DC Electronic Load
Table of Contents
Warranty Information
Safety Symbols
Front Panel
Quick Reference
Front Panel Display
Rear Panel
Front Panel Menus
Immediate Action Keys
Key Pad
Tran
Menu Operation
POWER-ON Recall
ADC Update Rate High Lowdefault
General Information
Options and Accessories
Document Orientation
Getting Started Map
Accessories
Features and Capabilities
Description
Front Panel Controls
Constant Voltage CV Mode
Constant Resistance CR Mode
Remote Programming
Operating Modes
Transient Operation
Constant Power CW Mode
Continuous
List Operation
Trigger Mode
Pulse
Input Control
Triggered Operation
Short On/Off
Input On/Off
Protection Features
Operation Range
Over Voltage
Over Temperature
Over Power
Pin trigger and remote sensing connectors
Remote Sense Function and Trigger Function
Wiring diagram for remote sense
Saving and Recalling Settings
Operation
Battery Testing
Action for set Von/Voff value
Von/Voff Operation
Inspection
Installation
Location
Outline Diagram
Power Cord
Bench Operation
Input Connections
Turn-On Checkout
Checkout Procedure
Introduction
Trigger and Remote Sensing Connections
Case of Trouble
Front Panel Operation
Display
Front Panel Display
Set set up a constant current from 0 to Max current
Power
Example
Function keys
Set set up a constant resistance from 0.1Ω to 4000Ω
Set set up a constant power from 0 to Max power
POWER=*.***W
000V
Set set up a constant voltage from 1.5V to Max voltage
Transition Testing Operation
On/Off input setting
Shift + Store
Continuous Transient Operation
Transition Parameter Setting
Pulse Transient Operation
Steps
Toggled Transient Operation
List Operation
Edit the Testing File
Automatic Testing Function of Electronic Load
Quick Recall Function
Enter
Setting the Resolution and number of decimal points
Automatic Testing
Range Accuracy Resolution
Specifications
Communication cable
Remote Operation Mode
IT-E131 RS232 Communication cable
IT-E132 USB Communication cable
Frame Format
Communication between electronic load and PC
IT-E132 communication
2AH
Communication Protocol
Selecting the Remote control mode(20H)
Setting / Reading the max input current .(24H/25H)
Setting / Reading max input voltage(22H/23H)
Selecting the input on/off state (21H)
Setting / Reading max input power(26H/27H)
Setting / Reading CV mode voltage value.(2CH/2DH)
Setting / Reading CC mode current value(2AH/2BH)
Setting / Reading CW mode watt value(2EH/2FH)
Setting / Reading CR mode resistance value(30H/31H)
26th byte Sum code
Setting / Reading the number of list steps EH/3FH
Setting /Reading the list repeat mode CH/3DH
Setting / Reading List file name 48H/49H
Save / Get list file in appointed area. CH/4DH
Setting / Reading timer value of for Load on 50H/51H)
Enable/Disable Local control mode H
Setting communication address 54H
Selecting / Reading trigger source H/59H
Reading input voltage, current, power and relative state FH
Sending a trigger signal to trigging the electronic load AH
BIT
Enter the calibration mode(60H)
Calibrate voltage value(62H)
Getting the calibration mode state(61H)
Calibrate current value(64H)
Setting / Reading calibration information(67H/68H)
Store the calibration data to EEPROM(66H)
For example:
Restore the factory default calibration data(69H)
Reading information in bar code 6BH
Setting information of bar code(6CH)
Limited One-Year Warranty
Service Information
Declaration of CE Conformity
Savi Ranch Parkway Yorba Linda, CA
Top
Page
Image
Contents