1st byte

Start bit ( AAH )

2nd byte

Address (0—0XFE)

3rd byte

Command 58H/59H

 

 

 

4th byte

Trigger mode (0:Keypad,1 External,2.command)

From 5th to 25th byte

System reserve

26th byte

Sum code

32. Sending a trigger signal to trigging the electronic load. (5AH)

1st byte

Start bit ( AAH )

2nd byte

Address (0—0XFE)

3rd byte

Command5AH

 

 

 

From 4th to 25th byte

System reserve

26th byte

Sum code

33.Saving / Recall user’s setting value in appointed memory area for recall. (5BH/5CH)

1st byte

Start bit ( AAH )

2nd byte

Address (0—0XFE)

3rd byte

Command5BH/5CH

 

 

 

4th byte

Storing area ( )

From 5th to 25th byte

System reserve

26th byte

Sum code

34.Selecting / Getting FIXED/SHORT/TRAN/LIST/ BATTERY function mode. (5DH/5EH)

1st byte

Start bit ( AAH )

2nd byte

Address (0—0XFE)

3rd byte

Command5DH/5EH

 

 

 

4th byte

Work mode (0:FIXED,1:SHORT, 2:TRANSITION,3:LIST,4: BATTERY)

From 5th to 25th byte

System reserve

26th byte

Sum code

35.Reading input voltage, current, power and relative state. (5FH)

1st byte

Start bit ( AAH )

2nd byte

Address (0—0XFE)

3rd byte

Command 5FH

 

 

 

From 4th to 7th byte

Actual input voltage value (Lower bytes are in the front location, higher bytes are in the

 

later location)

 

 

From 8th to 11th byte

Actual input current value (Lower bytes are in the front location, higher bytes are in the

 

 

49

Page 49
Image 49
B&K 8510 instruction manual Sending a trigger signal to trigging the electronic load AH